6150-01-361-0495

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL,BRANCHED


6150-01-361-0495 (6150013610495, 013610495)
Part Numbers (2 listings): 2849189-1 | 2849189 |
Summary

FSG 61 / FSC 6150

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 8 Jul 1992

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6150-01-361-0495 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2849189-13 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
2849189D - Drawing Number Reference9 - No Longer UsedRAYTHEON COMPANY  96214    CAGE 96214  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6150-01-361-0495 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616150013610495A077A060148X1ANA08 Jul 1992
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6150

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Electric Power and Distribution Equipment

013610495

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6150-01-361-0495

A077A0

Federal Item Identification Guide (FIIG_4065)

60148

Item Naming Code (INC_4080)

8 Jul 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6150-01-361-0495 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FMSGFGG400E1 Nov 2001
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.


FLIS - SEG C - REFERENCE NUMBER | NSN 6150-01-361-0495 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
322MG2849189-1  96214   CAGE/96214
D92MG2849189  96214   CAGE/96214
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

MG

Reference Number Action Activity Code (RNAAC_2900)


Engineering Data Support Center, Robbins AFB, GA 31098-5690

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6150-01-361-0495 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6CX010 Jul 1992
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Jul 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6150-01-361-0495 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TG
Code Definitions

TG

Originating Activity Code (ORIG_ACTY_CD_4210)


Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6150-01-361-0495 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFF2UPU1TEA0
Code Definitions

F2U

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner-Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1887

P

Acquisition Advice Code (AAC_2507)


RESTRICTED REQUISITION - SECURITY ASSISTANCE PROGRAM (SAP) 1. Indicates item is stocked or acquired only for SAP (replaces Military Assistance Program (MAP)) requirements, or 2. Indicates item is nonstocked and materiel is ordered from the contractor for shipment directly to the foreign government. 3. Base, post, camp, or station will not requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6150-01-361-0495 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationAN/APQ-171
CXQJBranch Quantity3
ASQBCable Assembly Overall Length204.000 INCHES MINIMUM AND 228.000 INCHES MAXIMUM
AMQNConductor Quantity15
MDCLMaterial Document And ClassificationQQ-B-575 FED SPEC 6TH MATERIAL RESPONSE 5TH POSITION SHIELD BRAID, METALLIC CABLEMIL-R-6855 MIL SPEC 7TH MATERIAL RESPONSE 6TH POSITION TUBE CABLE
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORSPLASTIC CROSS-LINKED POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORSCOPPER 5TH POSITION SHIELD BRAID, METALLIC CABLERUBBER 6TH POSITION TUBE CABLE
FEATSpecial FeaturesNOUN: WIRING HARNESS,BRANCHED,FLIGHT CONTROL SYSTEM (W5); WIRE/CABLE CONFORMS TO M27500-24ML2T08,M27500-24ML3T08 M81044/12-22-9; OVERALL SHIELDS CONFORM TO QQB575R36T109,QQB575R36T250; OVERALL SHIELDS CONNECTED TO BACKSHELLS OF P1,P2,P3; INDIVIDUAL CABLE SHIELDS ARE SPLICED TOGETHER AND TERMINATED AT P1-17; 13 CONDUCTORS USED WI2 CONDUCTORS DESIGNATED AS SPARES; P1-18 & 20 SHORTED
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORSTIN 5TH POSITION SHIELD BRAID, METALLIC CABLE
CXGNTerminal Commercial And Government Entity Code96906 1ST END ALL CONDUCTORS96906 2ND END ALL CONDUCTORS81349 3RD END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMS27467T23B35SC 1ST END ALL CONDUCTORSMS3476W22-55P 2ND END ALL CONDUCTORSM83723/78R1831N 3RD END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG ALL ENDS ALL CONDUCTORS