| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 2D60856PK-001 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 90099 | |
| 2D60856PK | D - Drawing Number Reference | 9 - No Longer Used | NORTHROP GRUMMAN SYSTEMS CORPORATION | 90099 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6150 | 013624527 | A077A0 | 00782 | X | 1 | B | N | A | 0 | 6 Aug 1992 |
Electric Wire, and Power and Distribution Equipment
Miscellaneous Electric Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FUGG | FUCX | 0 | 0 | Z | SU | 1 May 2005 | ||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 2 | ME | 2D60856PK-001 | 90099 | | ||||||
| D | 9 | 2 | ME | 2D60856PK | 90099 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
Engineering Data Support Center, Hill AFB, UT 84056-5609
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 6 Aug 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SU | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AGAV | End Item Identification | MX MISSILE; NHA = 1D96758PK |
| HUES | Color | WHITE CORE CONDUCTOR ALL CONDUCTORSWHITE 4TH POSITION JACKET ALL GROUPSBLACK 5TH POSITION SLEEVE CABLE |
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| CXDY | Conductor Grouping Arrangement Type And Quantity | 1 TWISTED PAIR FIRST GROUP1 TWISTED PAIR SECOND GROUP |
| AMQN | Conductor Quantity | 6 |
| CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR FIRST GROUP AND FOURTH CONDUCTOR FIRST GROUPFIFTH CONDUCTOR SECOND GROUP AND SIXTH CONDUCTOR SECOND GROUP |
| CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR |
| AAGR | Cross-Sectional Shape Style | ROUND |
| CXDT | Group Quantity | 2 |
| MDCL | Material Document And Classification | MIL-I-23053/1; -23053/1-203-O MIL SPEC 6TH MATERIAL RESPONSE 5TH POSITION SLEEVE CABLE |
| MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORSPLASTIC CROSS-LINKED POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORSCOPPER 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPSPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE 4TH POSITION JACKET ALL GROUPSRUBBER POLYCHLOROPRENE 5TH POSITION SLEEVE CABLE |
| CXDC | Round Conductor Size | 12 AWG 1ST CONDUCTOR12 AWG 2ND CONDUCTOR18 AWG 3RD CONDUCTOR18 AWG 4TH CONDUCTOR18 AWG 5TH CONDUCTOR18 AWG 6TH CONDUCTOR |
| FEAT | Special Features | 2NOUN: CABLE ASSY,CABLE REEL J-BOX TO MCSA; WIRE/CABLE CONFORMS TO M81044/12-12-9 & M27500-18ML2T08; SHIELDS AT P1,P2 ARE SPLICED USING M81044/12-22-9 WIRE,M83519/2-10 SPLICES,MS25036-148 TERMINAL LUGS,AND CONNECTED TO THE CONNECTOR BACKSHELLS |
| AAJU | Overall Length | 26.000 INCHES |
| ASGF | Tracer Color | BLUE SINGLE TRACER FOURTH CONDUCTORBLUE SINGLE TRACER SIXTH CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 28 1ST CONDUCTOR28 2ND CONDUCTOR30 3RD CONDUCTOR30 4TH CONDUCTOR30 5TH CONDUCTOR30 6TH CONDUCTOR |
| BLNZ | Strand Quantity Per Conductor | 37 1ST CONDUCTOR37 2ND CONDUCTOR19 3RD CONDUCTOR19 4TH CONDUCTOR19 5TH CONDUCTOR19 6TH CONDUCTOR |
| STYL | Style Designator | INTERNAL CONNECTORS |
| SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORSTIN 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPS |
| ABJH | Temp Rating | 150.0 DEG CELSIUS |
| CXGN | Terminal Commercial And Government Entity Code | 96906 1ST END ALL CONDUCTORS81349 2ND END ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | MS3456L20-18P 1ST END ALL CONDUCTORSD38999/46WJ24SN 2ND END ALL CONDUCTORS |
| AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |