6150-01-362-4527

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL


6150-01-362-4527 (6150013624527, 013624527)
Part Numbers (2 listings): 2D60856PK-001 | 2D60856PK |
Summary

FSG 61 / FSC 6150

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 6 Aug 1992

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6150-01-362-4527 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2D60856PK-0013 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  90099    CAGE 90099  
2D60856PKD - Drawing Number Reference9 - No Longer UsedNORTHROP GRUMMAN SYSTEMS CORPORATION  90099    CAGE 90099  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6150-01-362-4527 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616150013624527A077A000782X1BNA06 Aug 1992
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6150

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Electric Power and Distribution Equipment

013624527

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6150-01-362-4527

A077A0

Federal Item Identification Guide (FIIG_4065)

00782

Item Naming Code (INC_4080)

6 Aug 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6150-01-362-4527 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUGGFUCX00ZSU1 May 2005
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SU

Item Management Coding Activity (IMC_ACTY_2748)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609


FLIS - SEG C - REFERENCE NUMBER | NSN 6150-01-362-4527 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
322ME2D60856PK-001  90099   CAGE/90099
D92ME2D60856PK  90099   CAGE/90099
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ME

Reference Number Action Activity Code (RNAAC_2900)


Engineering Data Support Center, Hill AFB, UT 84056-5609

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6150-01-362-4527 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 Aug 1992
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Aug 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6150-01-362-4527 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SU743Z9AHZP061130X34350CABLE-ASSEMBLY
Code Definitions

SU

Originating Activity Code (ORIG_ACTY_CD_4210)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6150-01-362-4527 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSZU1NEA0
DSSMSZU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6150-01-362-4527 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationMX MISSILE; NHA = 1D96758PK
HUESColorWHITE CORE CONDUCTOR ALL CONDUCTORSWHITE 4TH POSITION JACKET ALL GROUPSBLACK 5TH POSITION SLEEVE CABLE
CXCWConductor FormSTRANDED ALL CONDUCTORS
CXDYConductor Grouping Arrangement Type And Quantity1 TWISTED PAIR FIRST GROUP1 TWISTED PAIR SECOND GROUP
AMQNConductor Quantity6
CXFGConductor Sequence Within GroupsTHIRD CONDUCTOR FIRST GROUP AND FOURTH CONDUCTOR FIRST GROUPFIFTH CONDUCTOR SECOND GROUP AND SIXTH CONDUCTOR SECOND GROUP
CXDQConductor Arrangement And Quantity2 SINGLES AND 2 TWISTED PAIR
AAGRCross-Sectional Shape StyleROUND
CXDTGroup Quantity2
MDCLMaterial Document And ClassificationMIL-I-23053/1; -23053/1-203-O MIL SPEC 6TH MATERIAL RESPONSE 5TH POSITION SLEEVE CABLE
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORSPLASTIC CROSS-LINKED POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORSCOPPER 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPSPLASTIC CROSS-LINKED POLYVINYLIDENE FLUORIDE 4TH POSITION JACKET ALL GROUPSRUBBER POLYCHLOROPRENE 5TH POSITION SLEEVE CABLE
CXDCRound Conductor Size12 AWG 1ST CONDUCTOR12 AWG 2ND CONDUCTOR18 AWG 3RD CONDUCTOR18 AWG 4TH CONDUCTOR18 AWG 5TH CONDUCTOR18 AWG 6TH CONDUCTOR
FEATSpecial Features2NOUN: CABLE ASSY,CABLE REEL J-BOX TO MCSA; WIRE/CABLE CONFORMS TO M81044/12-12-9 & M27500-18ML2T08; SHIELDS AT P1,P2 ARE SPLICED USING M81044/12-22-9 WIRE,M83519/2-10 SPLICES,MS25036-148 TERMINAL LUGS,AND CONNECTED TO THE CONNECTOR BACKSHELLS
AAJUOverall Length26.000 INCHES
ASGFTracer ColorBLUE SINGLE TRACER FOURTH CONDUCTORBLUE SINGLE TRACER SIXTH CONDUCTOR
CXDGStrand Awg Size Per Conductor28 1ST CONDUCTOR28 2ND CONDUCTOR30 3RD CONDUCTOR30 4TH CONDUCTOR30 5TH CONDUCTOR30 6TH CONDUCTOR
BLNZStrand Quantity Per Conductor37 1ST CONDUCTOR37 2ND CONDUCTOR19 3RD CONDUCTOR19 4TH CONDUCTOR19 5TH CONDUCTOR19 6TH CONDUCTOR
STYLStyle DesignatorINTERNAL CONNECTORS
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORSTIN 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPS
ABJHTemp Rating150.0 DEG CELSIUS
CXGNTerminal Commercial And Government Entity Code96906 1ST END ALL CONDUCTORS81349 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMS3456L20-18P 1ST END ALL CONDUCTORSD38999/46WJ24SN 2ND END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS ALL CONDUCTORS


Back to Top
Back to Top