6150-01-476-1033

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL,BRANCHED


6150-01-476-1033 (6150014761033, 014761033)
Part Number (1 listing): 16735-707-1
Summary

FSG 61 / FSC 6150

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 Jun 2000

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6150-01-476-1033 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
16735-707-13 - Design Control Reference2 - Production ItemBOEING COMPANY, THE  94756    CAGE 94756  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6150-01-476-1033 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616150014761033A077A060148X1ANBA026 Jun 2000
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6150

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Electric Power and Distribution Equipment

014761033

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6150-01-476-1033

A077A0

Federal Item Identification Guide (FIIG_4065)

60148

Item Naming Code (INC_4080)

26 Jun 2000

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6150-01-476-1033 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU400FEFH1 Jun 2000
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 6150-01-476-1033 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32CZZ16735-707-1  94756   CAGE/94756
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

C

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing. The drawing is available for unlimited use but under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6150-01-476-1033 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6CX028 Jun 2000
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Jun 2000

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6150-01-476-1033 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK743Z9AHZP061130X34350CABLE-ASSEMBLY
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6150-01-476-1033 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZCU1TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6150-01-476-1033 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationLGM-30G
AMEMBinding MethodBRAID AND SLEEVE AND TAPED AND WIRE BOUND
CXQJBranch Quantity5
ASQBCable Assembly Overall Length44.000 FEET NOMINAL
CBBLFeatures ProvidedELECTROSTATIC SENSITIVE
AMQNConductor Quantity8
MATTMaterialCOPPER ALLOY 101 CORE CONDUCTOR ALL CONDUCTORS OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MDCLMaterial Document And ClassificationASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
CXCYPart Name Assigned By Controlling AgencyCABLE ASSEMBLY,BATERY SIMULATORS POWER,W10
FEATSpecial FeaturesCABLE P/NS M27500-22TE2T14,M27500-16TE2T14; WIRE,ELEC P/NS M22759/16-20-9,M22759/16-16-9; BRAID WIRE P/NS QQB575R36T150,QQB575R36T781; NHA P/N 16600-707; U/O P/N CI 0009556
STDCSurface Treatment Document And ClassificationASTMB33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code81349 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code98278 2ND END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code98278 3RD END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code98278 4TH END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code98278 5TH END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberD38999/46FE26PN 1ST END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMD53-06E9-7S-3 4TH END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMD53-06E9-7S-4 5TH END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMD53-06E9-7S-N 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberMD53-06E9-7S-N 3RD END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG ALL ENDS ALL CONDUCTORS


Back to Top
Back to Top