Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
135-1363-1431-331 | 3 - Design Control Reference | 2 - Production Item | DIALIGHT CORPORATION | 83330 | ![]() |
TAG-7032-TA160RC | 5 - Replaced / Discontinued | 9 - No Longer Used | GENISCO FILTER CORP. | 07294 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
62 | 6210 | 002773163 | A065A0 | 00160 | X | K | A | N | U | 12 Aug 1973 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1997 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | CX | 135-1363-1431-331 | 83330 | ![]() | ||||||
5 | 9 | 4 | CX | B | TAG-7032-TA160RC | 07294 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 30 Aug 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | W | 761 | Z | 9 | A | H | Z | W | 109700 | Z | 55690 | LAMP-OR-LIGHTING-FIXTURES | 1 |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Rating Variable
Electric Lamps
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
TMQY | Furnished Items And Quantity | 1 HEXAGON NUT AND 1 LOCK WASHER |
MATT | Material | COPPER ALLOY BODY |
AXGY | Mounting Method | PANEL |
ADAV | Overall Diameter | 0.943 INCHES MINIMUM AND 0.963 INCHES MAXIMUM |
AEUJ | Lamp Base Type Accommodated | MINIATURE BAYONET |
AEWU | Lamp Bulb Size Designator | T-3 1/4 |
CRHX | Lamp Type Accommodated And Quantity | 1 NEON |
AEXD | Lens Color | RED SINGLE LIGHT 1ST POSITION HORIZONTAL |
CWJJ | Lens Face Surface Condition | SMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL |
CTRM | Lens Back Surface Condition | SMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL |
CSKH | Lens Light Transmission Characteristic | TRANSPARENT SINGLE LIGHT 1ST POSITION HORIZONTAL |
ATAS | Lens Mounting Method | SCREW IN |
AEXC | Lens Quantity | 1 |
CRQG | Lens Type | CYLINDRICAL, EXTERNAL THREAD SINGLE LIGHT 1ST POSITION HORIZONTAL |
ABHP | Overall Length | 2.438 INCHES NOMINAL |
AEXZ | Panel Accommodation Hole Diameter | 0.688 INCHES NOMINAL |
BZWG | Panel Thickness For Which Designed | 0.406 INCHES MAXIMUM |
CTDS | Transmitted Light Color | RED SINGLE LIGHT 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
STYL | Style Designator | ROUND FRAME, ROUND LENS TYPE |
SFTT | Surface Treatment | CHROMIUM BODY |
TTQY | Terminal Type And Quantity | 2 SCREW |