6210-00-617-1547

LIGHT,PANEL


6210-00-617-1547 (6210006171547, 006171547)
Part Numbers (5 listings): 2560767-2 | 273-3830-0171-101 | 8909984 | VBE406-14 | TT54-3830B7 |
Summary

FSG 62 / FSC 6210

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1961

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6210-00-617-1547 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2560767-23 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
273-3830-0171-1013 - Design Control Reference2 - Production ItemDIALIGHT CORPORATION  83330    CAGE 83330  
89099843 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
VBE406-145 - Replaced / Discontinued2 - Production ItemTHALES NEDERLAND B.V.  H0203    CAGE H0203  
TT54-3830B75 - Replaced / Discontinued2 - Production ItemDIALIGHT CORPORATION  83330    CAGE 83330  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6210-00-617-1547 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
626210006171547A065A000119X49ANU1 Jan 1961
Code Definitions

62

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Lighting Fixtures and Lamps

6210

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Indoor and Outdoor Electric Lighting Fixtures

006171547

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6210-00-617-1547

A065A0

Federal Item Identification Guide (FIIG_4065)

00119

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6210-00-617-1547 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
ZG011 Apr 1991
ZW011 Nov 1998
YW011 Aug 2001
ZU011 Aug 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6210-00-617-1547 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325HDD2560767-2  10001  
3324CXD8909984  18876   CAGE/18876
322CX273-3830-0171-101  83330   CAGE/83330
524CXTT54-3830B7  83330   CAGE/83330
3526ZGDVBE406-14  H0203   CAGE/H0203
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6210-00-617-1547 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6210-00-617-1547 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
761Z9AHZF109550X55910LAMPS-BULBS--ELEC-INCANDESCENT-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


761

Water Commodity Code (WRT_CMDTY_CD_9275)


Electric Lamps

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

109550

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

55910

Uniform Freight Classification (UFC_CD_MODF_3040)

LAMPS-BULBS--ELEC-INCANDESCENT-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6210-00-617-1547 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9GYU1EA0
Code Definitions

S9G

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Aviation, Richmond, VA 23297 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6210-00-617-1547 Submit RFQ
MRCDecoded RequirementClear Text Reply
TMQYFurnished Items And Quantity1 HEXAGON NUT AND 1 LOCK WASHER
MATTMaterialCOPPER ALLOY ILLUMINATION DIRECTING DEVICE
MATTMaterialCOPPER ALLOY BODY
AXGYMounting MethodPANEL
AEUJLamp Base Type AccommodatedMIDGET FLANGED
AEWULamp Bulb Size DesignatorT-1 3/4
CRHXLamp Type Accommodated And Quantity1 INCANDESCENT
CTRMLens Back Surface ConditionSMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL
AEXDLens ColorRED SINGLE LIGHT 1ST POSITION HORIZONTAL
CWJJLens Face Surface ConditionSMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL
CSKHLens Light Transmission CharacteristicTRANSLUCENT SINGLE LIGHT 1ST POSITION HORIZONTAL
ATASLens Mounting MethodSCREW IN
AEXCLens Quantity1
CRQGLens TypeFLAT, EDGE W/BOOT SINGLE LIGHT 1ST POSITION HORIZONTAL
ADAVOverall Diameter0.531 INCHES NOMINAL
ABHPOverall Length1.375 INCHES NOMINAL
AEXZPanel Accommodation Hole Diameter0.468 INCHES NOMINAL
BZWGPanel Thickness For Which Designed0.218 INCHES MAXIMUM
CTDSTransmitted Light ColorRED SINGLE LIGHT 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A
STYLStyle DesignatorTRAP TYPE
SFTTSurface TreatmentNICKEL BODY
SFTTSurface TreatmentNICKEL ILLUMINATION DIRECTING DEVICE
TTQYTerminal Type And Quantity2 SOLDER LUG


Back to Top
Back to Top