Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
911-1112-1533-525 | 3 - Design Control Reference | 9 - No Longer Used | DIALIGHT CORPORATION | 83330 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
62 | 6210 | 010698981 | A065A0 | 00160 | X | 1 | A | N | U | 28 Dec 1978 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
N9BZ | 3 | L | Z | GH | 1 May 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 4 | CX | 911-1112-1533-525 | 83330 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 761 | Z | 9 | A | H | Z | W | 109700 | Z | 55690 | LAMP-OR-LIGHTING-FIXTURES |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electric Lamps
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
FABRICATE OR ASSEMBLE # (NON-STOCKED ITEMS) National Stock Numbered items fabricated or assembled from raw materials and finished products as the normal method of support. Procurement and stockage of the items are not justified because of low usage or peculiar installation factors. Distinctions between local or centralized fabricate/assemble capability are identified by the Source of Supply Modifier in the Source of Supply Column of the Service Management Data Lists.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
TMQY | Furnished Items And Quantity | 1 KNURLED FLANGE RING AND 1 LOCK WASHER |
MATT | Material | ALUMINUM BODY |
AXGY | Mounting Method | PANEL |
AEUJ | Lamp Base Type Accommodated | MIDGET FLANGED |
AEWU | Lamp Bulb Size Designator | T-1 3/4 OR T-2 |
CRHX | Lamp Type Accommodated And Quantity | 1 INCANDESCENT |
CTRM | Lens Back Surface Condition | SMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL |
AEXD | Lens Color | AMBER SINGLE LIGHT 1ST POSITION HORIZONTAL |
CWJJ | Lens Face Surface Condition | SMOOTH SINGLE LIGHT 1ST POSITION HORIZONTAL |
CSKH | Lens Light Transmission Characteristic | TRANSPARENT SINGLE LIGHT 1ST POSITION HORIZONTAL |
ATAS | Lens Mounting Method | SCREW IN |
AEXC | Lens Quantity | 1 |
CRQG | Lens Type | CYLINDRICAL, EXTERNAL THREAD SINGLE LIGHT 1ST POSITION HORIZONTAL |
ADAV | Overall Diameter | 0.509 INCHES MAXIMUM |
ABHP | Overall Length | 1.469 INCHES NOMINAL |
AEXZ | Panel Accommodation Hole Diameter | 0.375 INCHES NOMINAL |
BZWG | Panel Thickness For Which Designed | 0.125 INCHES MAXIMUM |
FEAT | Special Features | ALTERNATE LAMP TYPE ACCOMMODATED: NEON |
CTDS | Transmitted Light Color | AMBER SINGLE LIGHT 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
STYL | Style Designator | ROUND FRAME, ROUND LENS TYPE |
SFTT | Surface Treatment | ANODIZE BODY |
TTQY | Terminal Type And Quantity | 2 SOLDER LUG |