6240-00-498-5971

LAMP,INCANDESCENT


6240-00-498-5971 (6240004985971, 004985971)
Part Numbers (7 listings): CM8605 | CM8-605 | PL7233S | 8605 | LTX8605 | PL8605 | 855331-1 |
Summary

FSG 62 / FSC 6240

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 17 Oct 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6240-00-498-5971 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CM86053 - Design Control Reference2 - Production ItemCHICAGO MINIATURE LIGHTING LLC  71744    CAGE 71744  
CM8-6055 - Replaced / Discontinued2 - Production ItemCHICAGO MINIATURE LIGHTING LLC  71744    CAGE 71744  
PL7233S5 - Replaced / Discontinued2 - Production ItemNU-CONCEPT SYSTEMS INC  58561      
86055 - Replaced / Discontinued2 - Production ItemLAMP INDUSTRY  08108      
LTX86055 - Replaced / Discontinued2 - Production ItemLAMPTRONIX CO LTD  61342    CAGE 61342  
PL86055 - Replaced / Discontinued9 - No Longer UsedPRECISION LAMP INC  58451      
855331-15 - Replaced / Discontinued9 - No Longer UsedRCA CORP  95301      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6240-00-498-5971 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
626240004985971A0790000727XM3APU17 Oct 1969
Code Definitions

62

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Lighting Fixtures and Lamps

6240

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electric Lamps

004985971

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6240-00-498-5971

A07900

Federal Item Identification Guide (FIIG_4065)

00727

Item Naming Code (INC_4080)

17 Oct 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6240-00-498-5971 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 2000
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6240-00-498-5971 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324CXCM8605  71744   CAGE/71744
52ECX8605  08108  
52ECXPL7233S  58561  
52ECXLTX8605  61342   CAGE/61342
524XNCM8-605  71744   CAGE/71744
59ECXBPL8605  58451  
4594CXB855331-1  95301  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

XN

Reference Number Action Activity Code (RNAAC_2900)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6240-00-498-5971 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX05 Oct 1972
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Oct 1972

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6240-00-498-5971 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XN761Z9AHZF109550X55910LAMPS-BULBS--ELEC-INCANDESCENT-NOI
Code Definitions

XN

Originating Activity Code (ORIG_ACTY_CD_4210)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

761

Water Commodity Code (WRT_CMDTY_CD_9275)


Electric Lamps

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

109550

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

55910

Uniform Freight Classification (UFC_CD_MODF_3040)

LAMPS-BULBS--ELEC-INCANDESCENT-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6240-00-498-5971 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9GVU1EA0
Code Definitions

S9G

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Aviation, Richmond, VA 23297 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6240-00-498-5971 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGDVEmitted Light CharacteristicWHITE
AFSVAverage Life Rating In Hours10000.0
CRPSBase StyleSUB-MIDGET FLANGED
CSJWBulb DesignatorT-1
CSMCBulb Light Transmission CharacteristicTRANSPARENT
CRSKBulb StyleT (TUBULAR)
CWGKBurning PositionANY ACCEPTABLE
CTQMCurrent Rating For Which Designed0.017 AMPERES NOMINAL
CBBLFeatures ProvidedHEAT RESISTANT GLASS
AFSPFilament DesignationC-2R
AFSXFilament Heavy Duty Service RatingNOT RATED
AFSTLight Output Rating0.005 SPHERICAL CANDLEPOWER NOMINAL SINGLE RATING
CWBFRated Average LifeHOURS
ABHPOverall Length0.375 INCHES NOMINAL
AMSEVoltage Rating5.000 VOLTS NOMINAL


Back to Top