Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
500GFL125V | 3 - Design Control Reference | 2 - Production Item | LAMP INDUSTRY | 08108 | |
500GFL125 | 3 - Design Control Reference | 2 - Production Item | GENERAL ELECTRIC CO | 24446 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
62 | 6240 | 005191174 | A07900 | 00727 | X | 4 | 9 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G810 | 0 | 0 | L | 1 Apr 1991 |
Not Established
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 0 | 1 | CX | 0 | 17 Nov 1969 | 6240000504522 | 10 May 1986 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGDV | Emitted Light Characteristic | WHITE |
AFSV | Average Life Rating In Hours | 800.0 |
CRPS | Base Style | MOGUL SCREW |
CSJW | Bulb Designator | G-40 |
CSMC | Bulb Light Transmission Characteristic | TRANSLUCENT |
CRSK | Bulb Style | G (GLOBULAR) |
CWGK | Burning Position | BASE DOWN TO HORIZONTAL |
CBBL | Features Provided | FILAMENT SHIELDING AND HEAT RESISTANT GLASS |
AFSP | Filament Designation | C-5 |
AFSX | Filament Heavy Duty Service Rating | NOT RATED |
AGDW | Light Center Length | 4.250 INCHES NOMINAL |
CSRJ | Light Intensity Distribution Feature | REFLECTIVE BOWL |
AFST | Light Output Rating | 800.000 LUMENS NOMINAL SINGLE RATING |
CWBF | Rated Average Life | HOURS |
ABHP | Overall Length | 7.062 INCHES MAXIMUM |
AMSE | Voltage Rating | 125.000 VOLTS NOMINAL |
BDWW | Wattage Rating | 500.000 WATTS |