6350-01-270-2922

RETINA SCAN,SECURITY IDENTIFICATION SYSTEM


6350-01-270-2922 (6350012702922, 012702922)
Part Numbers (2 listings): 128208 | AN-127960 |
Summary

FSG 63 / FSC 6350

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1988

Unit Weight: 36.0 lbs

Unit Size: 25in x 19in x 16.5in

Unit Pack Cube: 4.535 cu ft

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6350-01-270-2922 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1282083 - Design Control Reference9 - No Longer UsedISYS SECURITY SYSTEMS INC  61136      
1282083 - Design Control Reference9 - No Longer UsedISYS SECURITY SYSTEMS INC  61136      
AN-1279605 - Replaced / Discontinued9 - No Longer UsedEYEDENTIFY INC  76075      
AN-1279605 - Replaced / Discontinued9 - No Longer UsedISYS SECURITY SYSTEMS INC  61136      
AN-1279605 - Replaced / Discontinued9 - No Longer UsedISYS SECURITY SYSTEMS INC  61136      
AN-1279605 - Replaced / Discontinued9 - No Longer UsedEYEDENTIFY INC  76075      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6350-01-270-2922 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
636350012702922A2390077777XM1APA01 Jan 1988
Code Definitions

63

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Alarm, Signal and Security Detection Systems

6350

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Alarm, Signal, and Security Detection Systems

012702922

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6350-01-270-2922

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

1 Jan 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6350-01-270-2922 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59761 Jan 1988
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

1 Jan 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6350-01-270-2922 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA72DZ9AHZM012530X52340ALARM-HORN-SIGNAL-SOUND-WARNING
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

012530

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

52340

Uniform Freight Classification (UFC_CD_MODF_3040)

ALARM-HORN-SIGNAL-SOUND-WARNING

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6350-01-270-2922 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP41100036.0 lbs25in x 19in x 16.5in4.535 cu ft20.0 lbs15in x 12in x 8in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XNV00B17FM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

36.0 lbs

Unit Pack Weight (UP_WT_5153)

25in x 19in x 16.5in

Unit Pack Size (UP_SZ_5154)

4.535 cu ft

Unit Pack Cube (UP_CU_5155)

20.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

15in x 12in x 8in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

NV

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

17

Special Marking Code (SP_MKG_CD_5169)


Reusable container

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6350-01-270-2922 Submit RFQ
MRCDecoded RequirementClear Text Reply
TEXTGeneral Characteristics Item Description2SYSTEM CONTAINS HOST COMPUTER PROMS (SM10-SM),HEAD ALIGNMENT BAR,DOT-ALIGNMENT BAR,TAMPER ALARM; OPERATING VOLTAGE 115 AC; FREQUENCY RANGE 50 TO 60 HZ; WIDTH 12.2 IN.; HEIGHT 15.0 IN; DEPTH 8.0 IN.; OPERATING TEMPERATURE RANGE 0 TO 40 DEG CEL


Back to Top
Back to Top