6505-01-508-4409

PHENOBARBITAL SODIUM INJECTION,USP


6505-01-508-4409 (6505015084409, 015084409)
Part Numbers (4 listings): NDC00074-2343-31 | NDC00409-2343-31 | LUMINAL | 03-1056 |
Summary

FSG 65 / FSC 6505

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 21 May 2003

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6505-01-508-4409 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
NDC00074-2343-313 - Design Control Reference2 - Production ItemABBOTT LABORATORIES INC.  60060      
NDC00409-2343-313 - Design Control Reference2 - Production ItemHOSPIRA, INC.  3VBU6      
LUMINAL5 - Replaced / Discontinued1 - Incomplete Part NumberABBOTT LABORATORIES INC.  60060      
03-10565 - Replaced / Discontinued1 - Incomplete Part NumberDEFENSE LOGISTICS AGENCY  89875    CAGE 89875  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6505-01-508-4409 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656505015084409XAPA21 May 2003
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6505

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Drugs and Biologicals

015084409

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6505-01-508-4409

21 May 2003

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6505-01-508-4409 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6505-01-508-4409 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZNDC00409-2343-31  3VBU6  
4324ZZDNDC00074-2343-31  60060  
4514ZZD03-1056  89875   CAGE/89875
4514ZZDLUMINAL  60060  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG G - FREIGHT DATA | NSN 6505-01-508-4409 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
GX
Code Definitions

GX

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6505-01-508-4409 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSYQ1PGM
DFSMSYQ1PGM
DNSMSYQ1PGM
DSSMSYQ1PGM
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

Q

Controlled Item Inventory Code (CIIC_2863)


A drug or other controlled substance designated as a Schedule III, IV, or V item, in accordance with the Controlled Substance Act of 1970. Other sensitive items requiring limited access storage.

1

Quantity Unit Pack (QUP_6106)


1

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

M

Shelf Life Code (SLC_2943)


TYPE I (24 Months (2.00-Years) ) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life.

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6505-01-508-4409 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKJAActive Medicament Medicinal Strength60.000 MILLIGRAMS PHENOBARBITAL SODIUM PER MILLILITER
CQCTPrimary Container TypeSYRINGE
CRLKPrimary Container Content Quantity1.000 MILLILITERS
CSCWTotal Primary Container Quantity10
FEATSpecial Features1ML CARPUJECT SYRINGE, LUER LOCK, WITHOUT NEEDLE
AJUCAmerican Hospital Formulary Service Classification Number282404
AJCNProtective Storage FeatureSECURITY STORAGE
CXCYPart Name Assigned By Controlling AgencyPHENOBARBITAL INJECTION LUMINAL SODIUM 60MG/ML W/O NEEDLES 10S
CRYCControlled Substance ClassificationSCHEDULE IV


Back to Top
Back to Top