6515-00-059-5786

NEEDLE,HYPODERMIC


6515-00-059-5786 (6515000595786, 000595786)
Part Numbers (7 listings): NN1838R | BD305199 | 250024 | GGS945 | 2NN1838R | AIG007 | 613-4906 |
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1961

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-00-059-5786 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
NN1838R3 - Design Control Reference2 - Production ItemTERUMO CORP  62120      
BD3051993 - Design Control Reference2 - Production ItemKRASITY'S MEDICAL & SURGICAL SUPPLY,  2T036      
2500243 - Design Control Reference2 - Production ItemMG SCIENTIFIC INC  0B4J7      
GGS9454 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
2NN1838R5 - Replaced / Discontinued2 - Production ItemCARIDIAN BCT EUROPE NV  B6953      
2NN1838R5 - Replaced / Discontinued2 - Production ItemLABORATOIRES TERUMO FRANCE SA  FA2C4      
AIG0075 - Replaced / Discontinued2 - Production ItemCENTRAVET  FANL2      
613-49065 - Replaced / Discontinued2 - Production ItemVWR INTERNATIONAL BVBA  B0474      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6515-00-059-5786 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515000595786A2180007252X1ANU1 Jan 1961
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

000595786

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-00-059-5786

A21800

Federal Item Identification Guide (FIIG_4065)

07252

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6515-00-059-5786 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G572001 Apr 1991
V542001 Apr 1991
ZB011 Apr 2011
ZF011 Jan 2013
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established


FLIS - SEG C - REFERENCE NUMBER | NSN 6515-00-059-5786 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZ250024  0B4J7  
324ZZBD305199  2T036  
324ZZNN1838R  62120  
341375DGGS945  81348   CAGE/81348
4524ZBD613-4906  B0474  
4524ZBD2NN1838R  B6953  
4524ZFA2NN1838R  FA2C4  
4524ZFAAIG007  FANL2  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

ZB

Reference Number Action Activity Code (RNAAC_2900)


Belgium

ZF

Reference Number Action Activity Code (RNAAC_2900)


France

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-00-059-5786 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-00-059-5786 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6515-00-059-5786 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
VAIUAPG0
Code Definitions

I

Acquisition Advice Code (AAC_2507)


DIRECT ORDERING FROM A CENTRAL CONTRACT/SCHEDULE # (NON-STOCKED ITEMS) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/service supply policy. The item is covered by a centrally issued contractual document or by any multiple-award Federal Supply Schedule, which permits using activities to place orders directly on vendors for direct delivery to the user.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

A

Quantity Unit Pack (QUP_6106)


10

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-00-059-5786 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANNPCannula Bevel DesignationREGULAR
ANPCCannula Length1.500 INCHES NOMINAL
ANNNCannula Wall Thickness DesignationREGULAR
ANNMHub TypeLUER LOCK
ANNSNeedle Cannula Gage Designation And Location18 GAGE CANNULA
ZZZTNondefinitive Spec/Std DataNEEDLE GAGE 18,POINT STYLE A
ANNWImmediate Container TypeANY ACCEPTABLE
ANNXImmediate Container Quantity100
ANNQMaterial And Location
ANNQMaterial And LocationSTEEL, CORROSION RESISTING CANNULA
ANNYQuantity Within Each Immediate Container1
AKMXSterilityUNABLE TO DECODE
ANGDDisposition After Initial UseUNABLE TO DECODE
AGUCUnit Package Quantity100
STYLStyle DesignatorGENERAL PURPOSE W/STUB NEEDLE GAGE NUMBER(S)


Back to Top