6515-00-069-5905

NEEDLE,BIOPSY


6515-00-069-5905 (6515000695905, 000695905)
Part Number (1 listing): MX13-156
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 0.1 lbs

Unit Size:

Unit Pack Cube: 0.006 cu ft

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-00-069-5905 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MX13-1563 - Design Control Reference9 - No Longer UsedMILTEX INSTRUMENT COMPANY INC  07920      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6515-00-069-5905 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515000695905A2180022456X1ANA1 Jan 1963
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

000695905

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-00-069-5905

A21800

Federal Item Identification Guide (FIIG_4065)

22456

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6515-00-069-5905 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZP011 Apr 1991
A911A1113H1 Dec 2006
FSGMFSKX3H1 Dec 2006
N9BLN9LM3H1 Dec 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-00-069-5905 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-00-069-5905 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
651Z9AMZJ139640X70100NEEDLES-NOI-IN-BBLS-BXS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


651

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Medical and Surgical

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

139640

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

70100

Uniform Freight Classification (UFC_CD_MODF_3040)

NEEDLES-NOI-IN-BBLS-BXS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6515-00-069-5905 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSYJ1EA0
DFSMSYJ1EA0
DNSMSYJ1EA0
DSSMSYJ1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

J

Controlled Item Inventory Code (CIIC_2863)


Pilferage - Pilferage controls may be designated by the coding activity to items coded U (Unclassified) by recording the item to J.

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 6515-00-069-5905 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZZ0120.1 lbs0.006 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZZZ
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

012

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.006 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

ZZ

Intermediate Container Code (INTMD_CTNR_CD_5167)


Special requirement – See specific instructions or drawings provided.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-00-069-5905 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANEHDesign DesignationMENGHINI
STYLStyle DesignatorLIVER OR KIDNEY
ANPACannula Outside Diameter2.0 MILLIMETERS NOMINAL
ANPBCannula Inside Diameter1.8 MILLIMETERS NOMINAL
ANPCCannula Length120.0 MILLIMETERS NOMINAL
ANNQMaterial And LocationBRASS, GG-I-526, CLASS 8, ALLOY 360 HUB
ANNQMaterial And LocationBRASS, GG-I-526, CLASS 8, ALLOY 360 SECURITY STOP
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 302 CANNULA
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 302 OBTURATOR ROD
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 303 CANNULA
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 303 OBTURATOR ROD
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 316 CANNULA
ANNQMaterial And LocationSTEEL, GG-I-526, CLASS 3, TYPE 316 OBTURATOR ROD
ANNRSurface Treatment And LocationCHROMIUM-NICKEL PLATED, GG-I-526, CLASS 8 HUB
ANNRSurface Treatment And LocationCHROMIUM-NICKEL PLATED, GG-I-526, CLASS 8 SECURITY STOP
ANNMHub TypeLUER LOCK
FEATSpecial Features6-1/8 INCH; WITH STYLET AND ADJUSTABLE STOP
CXCYPart Name Assigned By Controlling AgencyNEEDLE BIOPSY KIDNEY MENGHINI 6-1/8 INCH


Back to Top