6515-00-140-6970

NEEDLE,HYPODERMIC


6515-00-140-6970 (6515001406970, 001406970)
Part Numbers (2 listings): M0N0JECT400 | 100-0212,HENRYSCHEIN,INC. |
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 10 Sep 1971

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-00-140-6970 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M0N0JECT4003 - Design Control Reference1 - Incomplete Part NumberSHERWOOD MEDICAL CO  05963      
100-0212,HENRY SCHEIN, INC.3 - Design Control Reference2 - Production ItemU S DEPT OF VETERANS AFFAIRS  88009    CAGE 88009  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6515-00-140-6970 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515001406970A2180007252X1ANU10 Sep 1971
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

001406970

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-00-140-6970

A21800

Federal Item Identification Guide (FIIG_4065)

07252

Item Naming Code (INC_4080)

10 Sep 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6515-00-140-6970 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G57V00L1 Apr 1991
V542001 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 6515-00-140-6970 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
331475DM0N0JECT400  05963  
32454100-0212,HENRY SCHEIN, INC.  88009   CAGE/88009
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

54

Reference Number Action Activity Code (RNAAC_2900)


Department of Veteran Affairs, Hines, IL 60141


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-00-140-6970 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-00-140-6970 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
54
Code Definitions

54

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Veteran Affairs, Hines, IL 60141

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6515-00-140-6970 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
VAIU0BX0
Code Definitions

I

Acquisition Advice Code (AAC_2507)


DIRECT ORDERING FROM A CENTRAL CONTRACT/SCHEDULE # (NON-STOCKED ITEMS) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/service supply policy. The item is covered by a centrally issued contractual document or by any multiple-award Federal Supply Schedule, which permits using activities to place orders directly on vendors for direct delivery to the user.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

BX

Unit of Issue (UI_3050)


Box - A rigid, three dimensional container of various sizes and material. Includes “carton”, “tray” and “crate”. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-00-140-6970 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANNPCannula Bevel DesignationSHORT
ANPCCannula Length1.000 INCHES NOMINAL
ANNNCannula Wall Thickness DesignationREGULAR
ANNMHub TypeTHREADED
ANNSNeedle Cannula Gage Designation And Location27 GAGE CANNULA
ANNXImmediate Container Quantity1
ANNWImmediate Container TypeCYLINDER, PLASTIC, RIGID
ANNQMaterial And LocationPLASTIC, POLYPROPYLENE HUB
ANNQMaterial And LocationSTEEL, FED STD 66, AISI 304/SAE 30304 CANNULA
ANNYQuantity Within Each Immediate Container1
AKMXSterilityUNABLE TO DECODE
ANGDDisposition After Initial UseUNABLE TO DECODE
AGUCUnit Package Quantity100
STYLStyle DesignatorDENTAL W/STUB NEEDLE GAGE NUMBER(S)
ANNRSurface Treatment And LocationSILICON CANNULA


Back to Top