6515-00-183-9903

CATHETER AND NEEDLE UNIT,INTRAVENOUS


6515-00-183-9903 (6515001839903, 001839903)
Part Number (1 listing): 2959
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 2 Mar 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-00-183-9903 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
29593 - Design Control Reference2 - Production ItemBECTON DICKINSON AND CO  31202      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6515-00-183-9903 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515001839903A2210029491X1ANA2 Mar 1973
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

001839903

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-00-183-9903

A22100

Federal Item Identification Guide (FIIG_4065)

29491

Item Naming Code (INC_4080)

2 Mar 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6515-00-183-9903 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
V542001 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established


FLIS - SEG C - REFERENCE NUMBER | NSN 6515-00-183-9903 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332675D2959  31202  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-00-183-9903 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-00-183-9903 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
54
Code Definitions

54

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Veteran Affairs, Hines, IL 60141

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6515-00-183-9903 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9MYU1PG0
VAIU0EA0
Code Definitions

S9M

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

I

Acquisition Advice Code (AAC_2507)


DIRECT ORDERING FROM A CENTRAL CONTRACT/SCHEDULE # (NON-STOCKED ITEMS) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/service supply policy. The item is covered by a centrally issued contractual document or by any multiple-award Federal Supply Schedule, which permits using activities to place orders directly on vendors for direct delivery to the user.

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-00-183-9903 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANHQCatheter Nominal Length1.250 INCHES
ANFSCore Fabrication MethodNOT WOVEN
ANEHDesign DesignationINTRAVENOUS
CBBLFeatures ProvidedSTERILE AND DISPOSABLE AND X-RAY OPACITY
ANHMNeedle Nominal Diameter0.025 INCHES
ANHPNeedle Nominal Length2.125 INCHES
ANHFNominal Diameter0.035 INCHES
ANNQMaterial And LocationSTEEL, CORROSION RESISTING NEEDLE AND PLASTIC,POLYTETRAFLUOROETYLENE CATHETER AND PLASTIC HUB AND PLASTIC PLUG AND PLASTIC SYRINGE
ANERShaft Eye Quantity1
ANFYPatient Size DesignationADULT
FEATSpecial FeaturesCOLOR CODED GREEN LUER LOCK ADAPTER HUB
STYLStyle DesignatorINTRAVENOUS CATHETER AND NEEDLE UNIT
ANFRSyringe Capacity1.0 CUBIC CENTIMETERS
ANFGTip TypeOPEN END


Back to Top