Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
S115/13GAGE3-1/2 IN. | 3 - Design Control Reference | 2 - Production Item | RANFAC CORP | 93336 | |
GGN196TYPE1STYLEAP0INTSTYLE2HUB | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6515 | 003487350 | A21800 | 07252 | X | 1 | A | N | A | 1 Jan 1963 |
Medical, Dental, and Veterinary Equipment and Supplies
Medical and Surgical Instruments, Equipment, and Supplies
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
ZU01 | 1 Sep 2007 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | ZZ | S115/13GAGE3-1/2 IN. | 93336 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KX | 1 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
651 | Z | 9 | A | M | Z | J | 139640 | X | 70100 | NEEDLES-NOI-IN-BBLS-BXS |
Instruments, Medical and Surgical
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Pilferage - Pilferage controls may be designated by the coding activity to items coded U (Unclassified) by recording the item to J.
1
Box - A rigid, three dimensional container of various sizes and material. Includes “carton”, “tray” and “crate”. *Requires a quantitative expression
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ANNP | Cannula Bevel Designation | REGULAR |
ANPC | Cannula Length | 3.375 INCHES MINIMUM AND 3.625 INCHES MAXIMUM |
ANNN | Cannula Wall Thickness Designation | REGULAR |
ZZZX | Departure From Cited Designator | AS MODIFIED BY MATERIAL AND LOCATION |
ZZZW | Departure From Cited Document | AS MODIFIED BY UNIT PACKAGE TYPE |
ANNM | Hub Type | LUER LOCK |
ANNS | Needle Cannula Gage Designation And Location | 13 GAGE CANNULA |
ZZZT | Nondefinitive Spec/Std Data | 1 TYPE AND A STYLE AND 2 STYLE |
CXCY | Part Name Assigned By Controlling Agency | NEEDLE HYPO C4A ASPIRATING-PNEUMOTHORAX 13 GAGE LUER LOCK REG 12S |
ANNX | Immediate Container Quantity | 1 |
ANNW | Immediate Container Type | RACK, CARDBOARD OR RACK, METAL OR RACK, PLASTIC |
ANNQ | Material And Location | |
ANNQ | Material And Location | BRASS HUB |
ANNQ | Material And Location | STEEL, CORROSION RESISTING CLEANING WIRE |
ANNY | Quantity Within Each Immediate Container | 12 |
FEAT | Special Features | D-DAY ITEM FOR DOD |
AGUC | Unit Package Quantity | 12 |
STYL | Style Designator | ASPIRATING-PNEUMOTHORAX W/STUB NEEDLE GAGE NUMBER(S) |
ANNR | Surface Treatment And Location | CHROMIUM HUB AND NICKEL PLATED HUB |