6515-01-174-9898

ANESTHESIA SET,EPIDURAL


6515-01-174-9898 (6515011749898, 011749898)
Part Number (1 listing): AK02000
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 25 Mar 1984

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-01-174-9898 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AK020003 - Design Control Reference2 - Production ItemARROW INTERNATIONAL, INC.  60791      
AK020003 - Design Control Reference2 - Production ItemARROW INTERNATIONAL, INC.  60791      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6515-01-174-9898 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515011749898A2380032376X49ANA25 Mar 1984
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

011749898

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-01-174-9898

A23800

Federal Item Identification Guide (FIIG_4065)

32376

Item Naming Code (INC_4080)

25 Mar 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG C - REFERENCE NUMBER | NSN 6515-01-174-9898 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324KXAK02000  60791  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-01-174-9898 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597625 Mar 1984
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

25 Mar 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-01-174-9898 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KX
Code Definitions

KX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-01-174-9898 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJJWComponent Quantity12
AJKDNonsupply Items And QuantitiesNEEDLE,18 GAGE-1; POLYTETRAFLUOROETHYLENE CATHETER,20 GAGE-1; INTRODUCER 22 GAGE BY 1-1/2 IN.-1; INTRODUCER 25 GAGE BY 1 IN.-1; FENESTRATED DRAPE-1; GAUZE PAD-1; SPONGE-1; 3 CC DISPOSABLE SYRINGE-1; .2 MICRON FILTER-1; 5 CC GLASS SYRINGE-1; 5 MICRON FILTER TUBE-1; 19 GAGE BY 1-1/2 IN. FILTER NEEDLE-1
FEATSpecial FeaturesSTERILE; DISPOSABLE; UNIT QTY 20 SET


Back to Top