6515-01-283-0156

SUTURE,NONABSORBABLE,SURGICAL


6515-01-283-0156 (6515012830156, 012830156)
Part Numbers (4 listings): X425H | 88-6-6-93AH | 8201859 | B425H |
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 27 Jul 1988

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-01-283-0156 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
X425H3 - Design Control Reference1 - Incomplete Part NumberETHICON, INC  10614    CAGE 10614  
88-6-6-93 AH5 - Replaced / Discontinued1 - Incomplete Part NumberAIR FORCE MEDICAL LOGISTICS OFFICE  66735    CAGE 66735  
82018595 - Replaced / Discontinued2 - Production ItemANSPEC PTY LTD  ZBF76      
X425H5 - Replaced / Discontinued2 - Production ItemJOHNSON & JOHNSON MEDICAL PTY LTD  Z1612      
B425H5 - Replaced / Discontinued9 - No Longer UsedETHICON, INC  10614    CAGE 10614  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6515-01-283-0156 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515012830156A2190012952X1ANA27 Jul 1988
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

012830156

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-01-283-0156

A21900

Federal Item Identification Guide (FIIG_4065)

12952

Item Naming Code (INC_4080)

27 Jul 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6515-01-283-0156 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
V542001 Jul 1994
ZA011 Dec 2006
A911A1113H1 Dec 2006
FSGMFSKX3H1 Dec 2006
N9BLN9LM3H1 Dec 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG C - REFERENCE NUMBER | NSN 6515-01-283-0156 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
316ZZX425H  10614   CAGE/10614
514KX88-6-6-93 AH  66735   CAGE/66735
4523ZAAX425H  Z1612  
4523ZAC8201859  ZBF76  
594KXBB425H  10614   CAGE/10614
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZA

Reference Number Action Activity Code (RNAAC_2900)


Australia

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

C

Reference Number Status Code (RNSC_2923)


The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-01-283-0156 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597027 Jul 1988
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

27 Jul 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-01-283-0156 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KX534Z9AMZJ056940X32570SUTURES-SURGICAL
Code Definitions

KX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

534

Water Commodity Code (WRT_CMDTY_CD_9275)


Medical Supplies (not requiring temperature control)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

056940

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

32570

Uniform Freight Classification (UFC_CD_MODF_3040)

SUTURES-SURGICAL

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6515-01-283-0156 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
VAIU3DZ0
DASMSYU0DZ0
DFSMSYU0DZ0
DNSMSYU0DZ0
DSSMSYU0DZ0
Code Definitions

I

Acquisition Advice Code (AAC_2507)


DIRECT ORDERING FROM A CENTRAL CONTRACT/SCHEDULE # (NON-STOCKED ITEMS) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/service supply policy. The item is covered by a centrally issued contractual document or by any multiple-award Federal Supply Schedule, which permits using activities to place orders directly on vendors for direct delivery to the user.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

3

Quantity Unit Pack (QUP_6106)


3

DZ

Unit of Issue (UI_3050)


Dozen - Twelve (12) of an item of supply.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

0

Quantity Unit Pack (QUP_6106)


No QUP

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-01-283-0156 Submit RFQ
MRCDecoded RequirementClear Text Reply
APWLArmed Suture Needle Style1/2 CIRCLE
APRHArmed Suture Needle Point StyleROUND TAPER
HUESColorGREEN
APTDEnd TypeSINGLE ARMED
APSHNeedle Design DesignationGENERAL CLOSURE
CXCYPart Name Assigned By Controlling AgencySUTURE NONABS PLASTIC POLYESTER SZ 1 30" L B3 1/2 CIR C7 RD TAPER 3S
ANNXImmediate Container Quantity36
ANNWImmediate Container TypePACKET, FOIL
ABRYLength30.000 INCHES NOMINAL
ANNQMaterial And LocationPLASTIC, POLYESTER SUTURE AND STEEL, CORROSION RESISTING NEEDLE
ANNYQuantity Within Each Immediate Container1
AJXESize Designator1
FEATSpecial FeaturesNEEDLE CT-1; ETHIBOND
AGUCUnit Package Quantity36
AKMXSterilitySTERILE
APZJStrand Fiber ArrangementBRAIDED


Back to Top