Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
HP43110MC W/REUSEABLE CONTAINER | 3 - Design Control Reference | 2 - Production Item | HEWLETT-PACKARD CO | 52620 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6515 | 012911199 | X | A | N | A | 23 Dec 1988 |
Medical, Dental, and Veterinary Equipment and Supplies
Medical and Surgical Instruments, Equipment, and Supplies
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
NSN Center Does Not Have An Explanation
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A911 | A111 | 1 | Z | 1 Dec 2006 | ||||||||||||||||||||||||||
FSGM | FSKX | 1 | Z | 1 Dec 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | KX | HP43110MC W/REUSEABLE CONTAINER | 52620 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KX | 0 | 24 Jan 1989 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
GX | |||||||||||||||
KX | 534 | Z | 9 | A | M | Z | F | 056680 | X | 32570 | DENTAL-MEDICAL-SURG-INST-R-MACHINE |
HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Medical Supplies (not requiring temperature control)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
150
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | Z | 57.2 lbs | 3.679 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ | ZZ | Z | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
Special requirements
Special requirement. See specific instructions or drawings provided.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
FEAT | Special Features | 120/230 VOLT,50/60 HZ,AC OR DC; WITH REUSABLE CONTAINER; PORTABLE; OPERATES FROM SELF-CONTAINED BATTERIES OR LINE POWER; BATTERIES SUPPLIED WITH THE UNIT; THE MONITOR-RECORDER MODULE AARE SEPERATE FOR INDEPENDENT USE; EACH MODULE W/VISUAL AND/OR LOW BATTERY WARNING ALARMS; THE DEFIBRILLATOR MODULE INCLUDES ADULT EXTERNAL PADDLES; ENERGY RANGE OF 40-320 JOULES AND 2 INTERMEDIATE VALUES; AND DEFIBRILLATOR PADDLES WHICH ALSO SERVE AS ECG ELECTRODES; THE MONITOR-RECORDER MODULE INCLUDES NON-FADE DISPLAY; 5 LEAD16 PIN CONNECTOR; FULLY SHEILDED 6 FT (1.8 METER) ELECTRODE CABLE; 4 HR CONTINUOUS OPERATION W/O USE OF EXTERNAL POWER SOURCE; AND 30 MIN HEART ACTIVITY RECORDING TIME |
CXCY | Part Name Assigned By Controlling Agency | DEFIBRILLATOR MONITOR RECORDER: 120/230V 50/60HZ AC OR DC |