6515-01-617-5261

ANALYZER,DEFIBRILLATOR-ELECTROCARDIOGRAPH


6515-01-617-5261 (6515016175261, 016175261)
Part Number (1 listing): LIFEPAK-CR-PLUS
Summary

FSG 65 / FSC 6515

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 Mar 2013

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6515-01-617-5261 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
LIFEPAK-CR-PLUS3 - Design Control Reference2 - Production ItemPHYSIO-CONTROL, INC.  28494      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6515-01-617-5261 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656515016175261T398-E45323X1ANAA826 Mar 2013
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6515

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Medical and Surgical Instruments, Equipment, and Supplies

016175261

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6515-01-617-5261

T398-E

Federal Item Identification Guide (FIIG_4065)

45323

Item Naming Code (INC_4080)

26 Mar 2013

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

8

ADPE Identification Code (ADPEC_0801)


ADP Components. Represents ADP component assemblies that are parts of analog, digital, or hybrid data processing devices.


FLIS - SEG B - MOE RULE DATA | NSN 6515-01-617-5261 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
WB011 Mar 2013
YB011 Jun 2013
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6515-01-617-5261 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDLIFEPAK-CR-PLUS  28494  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6515-01-617-5261 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597026 Mar 2013
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

26 Mar 2013

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6515-01-617-5261 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
WB
Code Definitions

WB

Originating Activity Code (ORIG_ACTY_CD_4210)


Austria

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6515-01-617-5261 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ACYRDc Voltage Rating11.7 VOLTS NOMINAL
ALSFInternal Battery AccommodationINCLUDED
FEATSpecial Features150 J TO 360 J OUTPUT ENERGY; LI-SO2CL2 LITHIUM SULFURYL CHLORIDE 11.7V 1.4 AMP-HOUR; 2 QUIK-PAK ELECTRODE PADS INCLUDED; INTERNAL DIGITAL MEMORY; ECG STORAGE MINIMUM 20 MINUTES PER PATIENT; WIFI ENABLED; VOICE INSTRUCTIONS, AUDIBLE TONES AND GRAPHICAL PROMPTS
ABFYOverall Depth9.500 INCHES NOMINAL
ABKWOverall Height4.200 INCHES NOMINAL
ABMKOverall Width8.000 INCHES NOMINAL


Back to Top