6520-00-935-9872

MANDREL,DENTAL HANDPIECE


6520-00-935-9872 (6520009359872, 009359872)
Part Number (1 listing): A-63-4
Summary

FSG 65 / FSC 6520

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 5 Jun 1968

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6520-00-935-9872 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
A-63-43 - Design Control Reference9 - No Longer UsedCOLTENE/WHALEDENT INC.  29929      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6520-00-935-9872 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656520009359872T243-J13913X1APA5 Jun 1968
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6520

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Dental Instruments, Equipment, and Supplies

009359872

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6520-00-935-9872

T243-J

Federal Item Identification Guide (FIIG_4065)

13913

Item Naming Code (INC_4080)

5 Jun 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6520-00-935-9872 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6520-00-935-9872 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
394KXA-63-4  29929  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101


FLIS - SEG G - FREIGHT DATA | NSN 6520-00-935-9872 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KX650Z9AMZF056680X32570DENTAL-MEDICAL-SURG-INST-R-MACHINE
Code Definitions

KX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

650

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Dental

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

056680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

32570

Uniform Freight Classification (UFC_CD_MODF_3040)

DENTAL-MEDICAL-SURG-INST-R-MACHINE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6520-00-935-9872 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1PG0
DASMSYU1PG0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6520-00-935-9872 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANEHDesign DesignationFRICTION
APGFDesign TypeSLOTTED
CBJZHandpiece Type For Which DesignedANGLE
AASLHead Diameter0.076 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
MATTMaterialSTEEL CORROSION RESISTING
CXCYPart Name Assigned By Controlling AgencyMANDREL DENTAL HANDPIECE LATCH-TYPE LONG AUTOMATIC CLUTCH 2S
SUPPSupplementary FeaturesFOR USE W/CONTRA-ANGLE HANDPIECE,6520-00-019-9267 AND DRIVING PIN,6520-00-935-9869 AND 6520-00-420-0508
AAZEShank Diameter0.090 INCHES MINIMUM AND 0.091 INCHES MAXIMUM
ABHPOverall Length0.870 INCHES NOMINAL
FEATSpecial FeaturesLATCH TYPE; LONG; AUTOMATIC CLUTCH; PIN DRIVING TYPE HEAD; FOR HOLDING AND DRIVING THREAD-FORMING PIN INTO PIN HOLE IN DENTIN OF TEETH FOR RETENTION OF RESTORATIONS IN THE THREAD-FORMING SCREW TECHNIQUE; SHAFT RELIEVED TO PREVENT ENGAGEMENT BY HANDPIECE CHUCK; CONE SHAPED CONTACT AREA PROVIDES CLUTCH ACTION
SFTTSurface TreatmentPASSIVATE


Back to Top
Back to Top