Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2411 | 3 - Design Control Reference | 9 - No Longer Used | PENNWALT CORP | 79555 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6525 | 002221340 | T140-C | 06317 | X | 4 | 3 | A | P | A | 1 Jul 1969 |
Medical, Dental, and Veterinary Equipment and Supplies
Imaging Equipment and Supplies: Medical, Dental, Veterinary
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 4 | KX | 2411 | 79555 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KX | 0 | 3 Mar 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KX | J | 656 | Z | 9 | A | M | Z | J | 063560 | A | 98185 | X-RAY-MACHINE-SUB-1 |
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
100.2
X-Ray Apparatus and Equipment
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions
Department of the Navy
Department of the Army
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ARQE | Electric Power Rating | 2400.0 WATTS NOMINAL |
AKYD | Accessory Components And Quantity | CASSETTE 1; FILM PROCESSING HANGARS 3; HEAD MEASURING CALIPERS 1; INTRA-ORAL MIDLINE LOCATORS 2 |
AQZF | Control Type | CABINET |
AMPS | Current Rating In Amps | 10.0 |
FREQ | Frequency In Hertz | 50.0 OR 60.0 |
APGF | Design Type | STATIONARY |
AAXX | Mounting Type | WALL |
APHE | Operation Method | AUTOMATIC |
CLPX | Radiographic Timer Type | EXPOSURE |
BPKZ | Rectification Type | HALF-WAVE |
FAAZ | Phase | SINGLE |
FEAT | Special Features | FOR REPLACEMENT CASSETTE ORDER 6525-00-222-1341; FOR REPLACEMENT TUBE TRANSFORMER HEAD ORDER 6525-00-222-1347 |
CLQF | Transformer Output Capacity | 10.0 OUTPUT MA AT 90 KV PEAK |
CLQD | Transformer Rectification Method | SELF-RECTIFYING |
ARNF | Tube Quantity | 1 |
CLPR | Tube Stand Mounting Type | BASE |
AWGH | Tube Type | LINE FOCUS |
CLPG | Tube Cooling Method | OIL |
CLPH | Tube Mounting Type | TUBE STAND |
ELEC | Voltage In Volts | 110.0 AND 125.0 |
SUPP | Supplementary Features | PATIENTS HEAD CONCENTRENTIC POSITIONER; PANOGRAPHIC; MOTOR DRIVEN CHAIR |