6525-00-226-0919

CASSETTE,RADIOGRAPHIC FILM


6525-00-226-0919 (6525002260919, 002260919)
Part Number (1 listing): 2907TM5
Summary

FSG 65 / FSC 6525

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1961

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6525-00-226-0919 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2907TM53 - Design Control Reference9 - No Longer UsedGAF CORP  26924      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6525-00-226-0919 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656525002260919T140-B01110X1APA1 Jan 1961
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6525

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Imaging Equipment and Supplies: Medical, Dental, Veterinary

002260919

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6525-00-226-0919

T140-B

Federal Item Identification Guide (FIIG_4065)

01110

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6525-00-226-0919 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A911A111001 Dec 2006
FSGMFSKX001 Dec 2006
N9BL001 Dec 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6525-00-226-0919 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6525-00-226-0919 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
656Z9AMZQ068980X19930FILM-X-RAY-PHOTOGRAPHIC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


656

Water Commodity Code (WRT_CMDTY_CD_9275)


X-Ray Apparatus and Equipment

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

Q

Less Than Truckload (CLAS_RTNG_CD_2770)


70

068980

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

19930

Uniform Freight Classification (UFC_CD_MODF_3040)

FILM-X-RAY-PHOTOGRAPHIC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6525-00-226-0919 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSYU1OEA0
DFSMSYU1EA0
DNSMSYU1EA0
DSSMSYU1FEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

O

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or economically unserviceable, dispose at organizational level; COAST GUARD: Reparable item. When uneconomically reparable, condemn and dispose at the organizational (user) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose of at organization level; NAVY: Unassigned

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

F

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6525-00-226-0919 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFFACover MaterialSTEEL, CORROSION RESISTING
CKWFFront Panel MaterialPLASTIC
ABRYLength17.000 INCHES NOMINAL
ABGLWidth14.000 INCHES NOMINAL
CLNRIntensifying Screen Quantity2
CLNNRated SpeedHIGH
FEATSpecial Features14 BY 17 INCHES; LINEAR FOCUSED TYPE; RIDGID,GIRDER TYPE FRAME; CONSISTS OF TWO 14 INCH HIGH SPEED X-RAY INTENSIFYING SCREENS WITH SPEED FACTOR OF 1.6,GRID RATIO 6 TO 1; LEAD STRIP GRID SEPERATED BY FIBER,PLASTIC,OR ALUMINUM INETERSPACES,TRANSPARENT TO X-RAYS; 90 LINES PER INCH; FOR USE WITH SCREEN; X-RAY INTENSIFYING,6525-00-726-9830 IN MILITARY MEDICAL FACILITIES
CXCYPart Name Assigned By Controlling AgencyCASSETTE RADIOGRAPHIC FILM 14 BY 17 INCHES CRS COVER PLAS PANEL


Back to Top
Back to Top