6525-01-343-3422

FILM,RADIOGRAPHIC


6525-01-343-3422 (6525013433422, 013433422)
Part Numbers (2 listings): CURIXORHTOSTL | 069017 |
Summary

FSG 65 / FSC 6525

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 10 Aug 1991

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6525-01-343-3422 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CURIX ORHTO STL3 - Design Control Reference1 - Incomplete Part NumberBAYER CORP  59710      
0690173 - Design Control Reference2 - Production ItemBAYER CORP  59710      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6525-01-343-3422 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656525013433422T140-B01914X43APS10 Aug 1991
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6525

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Imaging Equipment and Supplies: Medical, Dental, Veterinary

013433422

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6525-01-343-3422

T140-B

Federal Item Identification Guide (FIIG_4065)

01914

Item Naming Code (INC_4080)

10 Aug 1991

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 6525-01-343-3422 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
V542001 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established


FLIS - SEG C - REFERENCE NUMBER | NSN 6525-01-343-3422 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
314KXCURIX ORHTO STL  59710  
32454069017  59710  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

54

Reference Number Action Activity Code (RNAAC_2900)


Department of Veteran Affairs, Hines, IL 60141


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6525-01-343-3422 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597010 Aug 1991
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Aug 1991

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6525-01-343-3422 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
54
Code Definitions

54

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Veteran Affairs, Hines, IL 60141

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6525-01-343-3422 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
VAIU1PG5
DAS9MYU1APG5
DNS9MYU1PG5
Code Definitions

I

Acquisition Advice Code (AAC_2507)


DIRECT ORDERING FROM A CENTRAL CONTRACT/SCHEDULE # (NON-STOCKED ITEMS) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/service supply policy. The item is covered by a centrally issued contractual document or by any multiple-award Federal Supply Schedule, which permits using activities to place orders directly on vendors for direct delivery to the user.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

PG

Unit of Issue (UI_3050)


Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression

5

Shelf Life Code (SLC_2943)


TYPE II (18 Months (1.50-Years) ) - An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

S9M

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

A

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6525-01-343-3422 Submit RFQ
MRCDecoded RequirementClear Text Reply
CKWBCorner Cut TypeREGULAR
CXJTFilm Processing TypeORTHO
AKHBFilm Exposure Quantity1
BSMMSensitized Coating LocationBOTH SIDES
CQWBPaper Interleaving ApplicationNON-INTERLEAVED
AKHZContrast RatingMEDIUM
AESHBase MaterialPLASTIC, POLYESTER
AETFBase ColorGREEN
ARSEGranule SizeMEDIUM
AKGWEmulsion SensitivityGREEN
ABRYLength43.0 CENTIMETERS NOMINAL
ABGLWidth35.0 CENTIMETERS NOMINAL
FEATSpecial FeaturesCURIX ORTHO STL FILM; CGR FILM CHANGER
PRMTPrecious MaterialSILVER


Back to Top
Back to Top