| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 65 | 6530 | 007084425 | T265-C | 04494 | X | 1 | A | N | A | 1 Jan 1963 |
Medical, Dental, and Veterinary Equipment and Supplies
Hospital Furniture, Equipment, Utensils, and Supplies
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZH | ||||||||||||||||||||||||||||||
| ZR | ||||||||||||||||||||||||||||||
| ZU | ||||||||||||||||||||||||||||||
| ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| J | 534 | Z | 9 | A | M | Z | W | 179320 | Z | 88080 | STERILIZERS-NOI |
100.2
Medical Supplies (not requiring temperature control)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKYD | Accessory Components And Quantity | 1 FRAME,TRAY; 2 TRAY; 1 GAGE,COMPOUND STEAM FOR STERILIZING CHAMBER; 1 GAGE,STEAM PRESSURE,FOR OUTER JACKET; 1 PLATE,SPREADER OR DEFLECTOR; 1 REGULATOR,STEAM PRESSURE; 1 THERMOMETER,INDICATING; 1 TRAP,THERMOSTATIC; 1 VACUUM DRYING SYSTEM; 1 VALVE,OPERATING,AUTOMATICALLY CONTROLLED; 1 VALVE,SAFETY |
| CPMD | Closure Method | HINGED DOOR SECURED BY LOCKING LEVERS,HANDWHEEL OPERATED |
| BRXN | Heat Transfer Method | PRESSURE STEAM |
| BDWT | Heating Method | STEAM FROM REMOTE STEAM SOURCE |
| MATT | Material | NICKEL ALLOY AND STEEL CORROSION RESISTING |
| AAXX | Mounting Type | TUBULAR STAND AND CABINET |
| ZZZT | Nondefinitive Spec/Std Data | 1 TYPE AND B CLASS AND THIRD SIZE |
| AARX | Inside Diameter | 16.000 INCHES NOMINAL |
| ADJU | Inside Length | 24.000 INCHES NOMINAL |
| FEAT | Special Features | 1 GLASS WATER GAGE IF REQUIRED; 3 LAMP,NEON,NE-51 SPARE |