6530-01-192-9459

CONTAINER,ENVIRONMENTAL PROTECTION,MEDICAL SUPPLIES


6530-01-192-9459 (6530011929459, 011929459)
Part Number (1 listing): DEPOT-GOV'TFURNISHEDMATERIAL
Summary

FSG 65 / FSC 6530

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 27 Oct 1984

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6530-01-192-9459 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
DEPOT-GOV'T FURNISHED MATERIAL3 - Design Control Reference1 - Incomplete Part NumberDEFENSE LOGISTICS AGENCY  89875    CAGE 89875  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6530-01-192-9459 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656530011929459XANA27 Oct 1984
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6530

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hospital Furniture, Equipment, Utensils, and Supplies

011929459

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6530-01-192-9459

27 Oct 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6530-01-192-9459 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A911A1111G19 Jan 2007
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.


FLIS - SEG C - REFERENCE NUMBER | NSN 6530-01-192-9459 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
314ZZDEPOT-GOV'T FURNISHED MATERIAL  89875   CAGE/89875
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6530-01-192-9459 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597027 Oct 1984
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

27 Oct 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6530-01-192-9459 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
GX
KX534Z9AMZZ000000X00000NO-NMFC-FREIGHT-DESCRIPTION
Code Definitions

GX

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060

KX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

534

Water Commodity Code (WRT_CMDTY_CD_9275)


Medical Supplies (not requiring temperature control)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

Z

Less Than Truckload (CLAS_RTNG_CD_2770)


No Rating

000000

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

00000

Uniform Freight Classification (UFC_CD_MODF_3040)

NO-NMFC-FREIGHT-DESCRIPTION

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6530-01-192-9459 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU1EA0
DASMSYU0OEA0
DFSMSYU0EA0
DSSMSYU0FEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

0

Quantity Unit Pack (QUP_6106)


No QUP

O

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or economically unserviceable, dispose at organizational level; COAST GUARD: Reparable item. When uneconomically reparable, condemn and dispose at the organizational (user) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose of at organization level; NAVY: Unassigned

F

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6530-01-192-9459 Submit RFQ
MRCDecoded RequirementClear Text Reply
TEXTGeneral Characteristics Item DescriptionINSULATED; 120 VOLT; 50/60/400 HZ,AC OR 28 VOLT,DC; TOPLOADING; RIGID POLYURETHANE FOAM INSULATION WITH ALUMINUM INTERIOR AND EXTERIOR SHELLS; 16 CU FT (453,068 CU CM) INTERNAL VOLUME; 6 CU FT (169,900 CU CM) INTERNAL VOLUME; WITH RECESSED HANDLE ON EACH OF THE FOUR SIDES; SKIDS; POWER CABLE; ADAPTER CABLES; REMOTE VISUAL AND AUDIBLE ALARM,ANN 20 FT (6 METER) ALARM CABLE; MAINTAINS TEMPERATURE BETWEEN 35 DEG AND 45 DEG F. (1.7 DEG AND 7.2 DEG C) WITH EXTERNAL ENVIRONMENTAL TEMPERATURES RANGING FROM -5 DEG TO -60 DEG F (-37 DEGS TO -51 DEG C); RELATIVE HUMIDITIES AT SATURATION; AND WIND SPEEDS OF 16 FT (4.9 METERS) PER SECOND; WILL MAINTAIN FREEZABLE MEDICAL ITEMS AT OR ABOVE FREEZING FOR EIGHT HOURS WITHOUT POWER; USED TO SUPPORT DAILY OPERATIONS; TACTICAL MOVES; DEPOT TO UNIT SHIPMENTS,AND BOTH WAREHOUSE AND OUTSIDE STORAGE OF MEDICAL SUPPLIES SUBJECT TO DAMAGE BY FREEZING IN AN ARCTIC ENVIRONMENT; 125 LB. MAX. WGT. EXCLUDING POWER CABLE AND SUPPLY ADAPTER CABLE
CXCYPart Name Assigned By Controlling AgencyCONTAINER ENVIRONMENTAL PROTECT ON:


Back to Top
Back to Top