Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
90-0449P | 3 - Design Control Reference | 2 - Production Item | DEFENSE MEDICAL STANDARDIZATION | 64616 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6530 | 013198234 | A23900 | 77777 | X | 4 | 1 | A | N | A | 16 May 1990 |
Medical, Dental, and Veterinary Equipment and Supplies
Hospital Furniture, Equipment, Utensils, and Supplies
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name does not exist.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A911 | A111 | 1 | G | 1 Dec 2006 | ||||||||||||||||||||||||||
FSGM | FSKX | 1 | G | 1 Dec 2006 | ||||||||||||||||||||||||||
N9BL | 1 | G | 1 Dec 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | KX | 90-0449P | 64616 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KX | 0 | 16 May 1990 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KX | 656 | Z | 9 | A | M | Z | F | 056680 | X | 32570 | DENTAL-MEDICAL-SURG-INST-R-MACHINE |
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
X-Ray Apparatus and Equipment
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
150
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
RESTRICTED REQUISITIONING-SPECIAL INSTRUCTIONS APPLY (NON-STOCKED ITEMS) Indicates stock number has been assigned to a generic item for use in bid invitations, allowance lists, etc., against which no stocks are ever recorded. Requisitions will be submitted only in accordance with IMM/Service requisitioning procedures. (This code will be used, when applicable, in conjunction with Phrase Code S (Stock as NSN(s)). It is considered applicable for use when a procurement source(s) becomes available. The Phrase Code S and the applicable ?stock as? NSN(s) will then be applied for use in stock, store and issue actions.)
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
TEXT | General Characteristics Item Description | PORTABLE; BTRY OR LINE PWRED; 12 TO 30 V, DC OR 115/220 V, 50 TO 400 HZ; SINGLE PHASE,AC; IN CARRYING CASE; C/O COMPRESSION MECHANISM,GAS BLENDER,STORAGE RESERVOIR CONTROL CIRCUITRY; RECHARGEABLE BTRY PACK; ELECTRICAL CONNECTIONS FOR BTRY RECHARGE OPERATION; PWR CORD 6 FT LG VEHICLEASSEMBLY AND CONNECTING HOSE; FOR USE IN HOSPITAL,AMBULANCE,FIE LD AND IN MILITARY AEROMEDICAL AIRCRAFT; PROVIDES DRY,100 PCT OIL FREE,AMBIENT AIR TO PORTABLE VOLUME VENTILATOR,6530-01-292-1049 AND ALLOWS THE VENTILATOR TO OPERATE USING 7 PSIG; MEETS AEROMEDICAL CERTIFICATION REQUIRMENTS |
FEAT | Special Features | COMPRESSOR SYSTEM MAY HAVE CONTROLS THAT SUPERSEDE VENTILATORS CONTROLS AND ALLOW PEAK AIRFLOW OF 40 LPM W/INSPRIATORY OF 1 SECOND; VENTILATOR IS CAPABLE OF DELIVERING PEAK TIDAL VOLUMES 0 TO 300 ML IN 0.5 SEC; 0 TO 700 ML IN 1 SEC; 0 TO 900 ML IN 1.5 SEC; 0 TO 1100 ML IN 2 SECONDS; COMPRESSOR COMPATIBLE ONLY W/VENTILATOR 6530-01-292-1049; REQUISITIONER MUST SPECIFY MAKE AND MODEL NUMBER OF VENTILATOR WHEN ORDERING COMPRESSOR |
ECWT | Exterior Container Weight | 33.00 POUNDS |
CXCY | Part Name Assigned By Controlling Agency | COMPRESSOR AND OXYGEN BLENDER VENTILATOR 115/220V 50 TO 400HZ |