6530-01-491-9093

STERILIZER,SURGICAL INSTRUMENT


6530-01-491-9093 (6530014919093, 014919093)
Part Number (1 listing): SYSTEM1
Summary

FSG 65 / FSC 6530

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 5 Nov 2001

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6530-01-491-9093 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SYSTEM 13 - Design Control Reference2 - Production ItemSTERIS CORPORATION  0NWN1      
SYSTEM 13 - Design Control Reference9 - No Longer UsedAMERICAN STERILIZER COMPANY  02964      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6530-01-491-9093 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656530014919093T265-C04495X1ANAA05 Nov 2001
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6530

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hospital Furniture, Equipment, Utensils, and Supplies

014919093

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6530-01-491-9093

T265-C

Federal Item Identification Guide (FIIG_4065)

04495

Item Naming Code (INC_4080)

5 Nov 2001

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6530-01-491-9093 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Nov 2001
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6530-01-491-9093 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3259ZSYSTEM 1  0NWN1  
43949ZDSYSTEM 1  02964  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6530-01-491-9093 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59705 Nov 2001
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Nov 2001

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6530-01-491-9093 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

MM

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6530-01-491-9093 Submit RFQ
MRCDecoded RequirementClear Text Reply
BDWTHeating MethodSTEAM FROM REMOTE STEAM SOURCE
MATTMaterialPLASTIC
AZKJMotor Current TypeAC
AZKKMotor Voltage In Volts120.0
AZCJIndividual Motor Quantity1
ABKWOverall Height32.000 INCHES NOMINAL
ABHPOverall Length24.000 INCHES NOMINAL
ABMKOverall Width38.000 INCHES NOMINAL
FEATSpecial FeaturesAUTOMATED, SELF CONTROLLED DEVICE WHICH CREATES, MONITORS AND MAINTAINS: PROCESSING TEMP 50 TO 55 DEG C; 12 MIN STERILIZATION/EXPOSURE TIME; FLUID CIRCULATION DURING RINSE/STERILIZATION CYCLES; STERILIZATION OF TAP WATER THRU FILTRATION MEMBRANE; 4 STERILE WATER RINSES; CONCENTRATION OF STERILANT USE DILATION; STERIS 20 STERILANT CONCENTRATE: ACXTIVE INGREDIENT PERACETIC ACID, NON TOXIC, NOT FOR RE USE; DESIGNED FOR THE STERILIZATION OF SURGICAL INSTRUMENTS; WARNING: EXPLOSION RISK IF USED NEAR FLAMMABLE ANESTHETICS


Back to Top
Back to Top