6530-01-539-2250

TRAY,CATHETER,CENTRAL VENOUS


6530-01-539-2250 (6530015392250, 015392250)
Part Number (1 listing): CV-17702-E
Summary

FSG 65 / FSC 6530

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 13 Apr 2006

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6530-01-539-2250 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CV-17702-E3 - Design Control Reference2 - Production ItemARROW INTERNATIONAL, INC.  60791      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6530-01-539-2250 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656530015392250T265-D53046X1ANAA013 Apr 2006
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6530

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hospital Furniture, Equipment, Utensils, and Supplies

015392250

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6530-01-539-2250

T265-D

Federal Item Identification Guide (FIIG_4065)

53046

Item Naming Code (INC_4080)

13 Apr 2006

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6530-01-539-2250 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Apr 2006
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6530-01-539-2250 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDCV-17702-E  60791  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6530-01-539-2250 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597013 Apr 2006
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Apr 2006

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6530-01-539-2250 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZW
Code Definitions

ZW

Originating Activity Code (ORIG_ACTY_CD_4210)


Turkey

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6530-01-539-2250 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And Quantity1 TWO LUMEN INDWELLING CATHETER 7 FR X 8 IN, RADIOPAQUE POLYURETHANE WITH BLUE FLEXTIP EXTENSION LINE CLAMPS INJECTION SITE CAPS; 1 SPRING WIRE GUIDE MARKED 0.032 INCH DIA X 23 5/8 INCH, STRAIGHT SOFT TIP ON ONE END-J TIP ON OTHER, WITH ARROW ADVANCER; 1 FASTENER CATHETER CLAMP; 1 INTRODUCER NEEDLE18 GA X 2 1/2 INCH XTW; 1 PRESSURE TRANSDUCTION PROBE; 1 ARROW RAULERSON SPRING WIRE INTRODUCTION SYRINGS 5 CC; 1 TISSUE DILATOR; 1 CLAMP CATHETER
MATTMaterialPLASTIC POLYETHYLENE
CXCYPart Name Assigned By Controlling AgencyTWO-LUMEN CENTRAL VENOUS CATHETER WITH BLUE FLEXTIP CATHETER 10/CASE
ALCDUsage DesignCARDIAC ASSIST, CRITICAL CARE


Back to Top
Back to Top