Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MILGUDI-1 | 3 - Design Control Reference | 2 - Production Item | GYRUS ACMI L.P. | 02033 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6545 | 012843035 | X | A | P | A | 22 Aug 1988 |
Medical, Dental, and Veterinary Equipment and Supplies
Replenishable Field Medical Sets, Kits, and Outfits
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
NSN Center Does Not Have An Explanation
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A911 | A111 | 3 | Z | 1 Dec 2006 | ||||||||||||||||||||||||||
FSGM | FSKX | 3 | Z | 1 Dec 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | KX | MILGUDI-1 | 02033 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KX | 0 | 4 Feb 2002 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
GX | |||||||||||||||
KX | 534 | Z | 9 | A | M | Z | F | 056680 | X | 32570 | DENTAL-MEDICAL-SURG-INST-R-MACHINE |
HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Medical Supplies (not requiring temperature control)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
150
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
No QUP
ARMY: If condemned or economically unserviceable, dispose at organizational level; COAST GUARD: Reparable item. When uneconomically reparable, condemn and dispose at the organizational (user) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose of at organization level; NAVY: Unassigned
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
TEXT | General Characteristics Item Description | MILIARY FLD USE AT SURGICAL EVACUATION HOSP; 110/220 V,50/60 HZ,AC; C/O CASE,ENDOSCOPIC INSTRUMENTS,PLASTIC-1; TELESCOPE,ENDOSCOPIC INSTRUMENT,UROLOGICAL LATERAL-2; TELESCOPE,ENDOSCOPIC INSTRUMENT,UROLOGICAL OBLIQUE-1; LIGHT ENDOSCOPIC INSTRUMENT,FIBER OPTIC,SINGLE 115 V,50/60 HZ-1; SHEATH,CYSTOURETHROSCOPE 10-1/2 IN. 21 FR-1; SHEATH,CYSTOURETHROSCOPE 10-1/2 IN. 23 FR-1; SHEATH,CYSTOURETHROSCOPE 10-1/2 IN. 25 FR-1; SHEATH,CYSTOURETHROSCOPE 10-1/2 IN. 17 FR-1; OBTURATOR,ENDOSCOPIC INSTRUMENT,VISUAL 21 FR-1; OBTURATOR,ENDOSCOPIC INSTRUMENT,UROLOGICAL,VISUAL 23 FR-1; BRIDGE,ENDOSCOPIC INSTRUMENT,UROLOGICAL DOUBLE CATHETERIZING ALBARRAN 10-1/2 IN.-1; BRIDGE,ENDOSCOPIC INSTRUMENT UROLOGICAL OPERATING ALBARRAN 10-1/2 IN.-1; OBTURATOR,ENDOSCOPIC INSTRUMENT,UROLOGICAL,VISUAL 25 FR-1; BRIDGE ENDOSCOPIC INSTRUMENT,UROLOGICAL,EXAMINING 1-7/8 IN.-1; CABLE ASSY,FIBER OPTIC,GLASS-2; BRIDGE,ENDOSCOPIC INSTRUMENT UROLOGICAL |
ECWT | Exterior Container Weight | 37.00 POUNDS |
SUCB | Unit Of Issue Cube | 3.28 CUBIC FEET |
CXCY | Part Name Assigned By Controlling Agency | GENITOURINARY CYSTOSCOPIC KIT: |