6550-01-119-7249

TEST STRIPS AND COLOR CHART,BILIRUBIN,BLOOD,GLUCOSE,KETONE,LEUKOCYTES,PH,PROTEIN,AND UROBILINOGEN IN URINE


6550-01-119-7249 (6550011197249, 011197249)
Part Numbers (6 listings): 417109 | U2230-2A | U2230-2B | U1260A | CHEMSTRIP9 | BC41709 |
Summary

FSG 65 / FSC 6550

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Oct 1981

Unit Weight: 0.3 lbs

Unit Size:

Unit Pack Cube: 0.020 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6550-01-119-7249 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
4171093 - Design Control Reference2 - Production ItemBOEHRINGER MANNHEIM CORP  32239      
U2230-2A3 - Design Control Reference9 - No Longer UsedCARDINAL HEALTH 200, LLC  07TA6    CAGE 07TA6  
U2230-2B5 - Replaced / Discontinued2 - Production ItemCARDINAL HEALTH 200, LLC  07TA6    CAGE 07TA6  
U1260A5 - Replaced / Discontinued2 - Production ItemCD ACQUISITION HOLDINGS INC  64767      
CHEMSTRIP 95 - Replaced / Discontinued9 - No Longer UsedBOEHRINGER MANNHEIM CORP  32239      
4171095 - Replaced / Discontinued9 - No Longer UsedROCHE DIAGNOSTICS CORPORATION  51169      
BC417095 - Replaced / Discontinued9 - No Longer UsedFISHER SCIENTIFIC COMPANY L.L.C.  22527    CAGE 22527  
U2230-2A5 - Replaced / Discontinued9 - No Longer UsedBAXTER HEALTHCARE CORP  22353      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6550-01-119-7249 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
656550011197249A1000047076X43APA1 Oct 1981
Code Definitions

65

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Medical, Dental, and Veterinary Equipment and Supplies

6550

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


In Vitro Diagnostic Substances, Reagents, Test Kits and Sets

011197249

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6550-01-119-7249

A10000

Federal Item Identification Guide (FIIG_4065)

47076

Item Naming Code (INC_4080)

1 Oct 1981

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6550-01-119-7249 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
V542001 Apr 1991
A911A1113Z1 Dec 2006
C922C0093Z1 Dec 2006
FSGMFSKX3Z1 Dec 2006
N9BLN9LM3Z1 Dec 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG C - REFERENCE NUMBER | NSN 6550-01-119-7249 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32654D417109  32239  
395ZZU2230-2A  07TA6   CAGE/07TA6
524ZZU2230-2B  07TA6   CAGE/07TA6
524KXU1260A  64767  
59654BCHEMSTRIP 9  32239  
595ZZB417109  51169  
59654BU2230-2A  22353  
594KXBBC41709  22527   CAGE/22527
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

54

Reference Number Action Activity Code (RNAAC_2900)


Department of Veteran Affairs, Hines, IL 60141

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6550-01-119-7249 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX012 Dec 1986
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

12 Dec 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6550-01-119-7249 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
54
Code Definitions

54

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Veteran Affairs, Hines, IL 60141

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6550-01-119-7249 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
VAG36YUFBTM
DASMSLU1COM
DFSMSLU1COM
DNSMSLU1COM
DSSMSLU1COM
GPSMSLU1COM
Code Definitions

G36

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Veterans Administration, 54 Supply Depot (901E) P.O. Box 27, Hines, IL 60141

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

F

Quantity Unit Pack (QUP_6106)


20

BT

Unit of Issue (UI_3050)


Bottle - A glass, plastic, or earthenware container of various sizes, shapes, and finishes such as jugs but excluding jars, ampoules, vials, and carboys, with a closure for retention of contents. *Requires a quantitative expression

M

Shelf Life Code (SLC_2943)


TYPE I (24 Months (2.00-Years) ) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life.

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.

1

Quantity Unit Pack (QUP_6106)


1

CO

Unit of Issue (UI_3050)


Container - A general term for use only when an item is permitted to be packaged for issue in optional containers, e.g., bottle or tube for a single National Stock Number. *Requires a quantitive expression

VA

Service / Agency Code (MOE_CD_2833)


Veterans Administration

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 6550-01-119-7249 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZZ0.3 lbs0.020 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZZZZM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

0.3 lbs

Unit Pack Weight (UP_WT_5153)

0.020 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Z

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Special requirement. See specific instructions or drawings provided.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6550-01-119-7249 Submit RFQ
MRCDecoded RequirementClear Text Reply
MATTMaterialPLASTIC
CQCTPrimary Container TypeANY ACCEPTABLE
CBBLFeatures ProvidedDESICCANT AGENT
FEATSpecial FeaturesREADING FROM TOP TO BOTTOM,THE NINE REAGENT AREAS SHALL BE LOCATED IN THE FOLLOWING ORDER: LEUKOCYTES,NITRITE,PH,PROTEIN,GLUCOSE,KETONE,UROBILINOGEN,BILIRUBIN,AND BLOOD; FINAL RESULTS SHALL BE OBTAINED IN 60 SECONDS OR LESS EXCEPT FOR LEUKOCYTES WHICH CAN BE READ AT 120 SECONDS; FOR SEMIQUANTITATIVE DETERMINATIONS
CXCYPart Name Assigned By Controlling AgencyTEST STRIPS&COLOR BILIRUBIN BLD GLUCOSE KETONE LEUKOCYTES PH


Back to Top