6610-01-398-8091

PROCESSOR,FLIGHT INFORMATION


6610-01-398-8091 (6610013988091, 013988091)
Part Numbers (2 listings): 5050062-9 | CP-2280/ASQ-219 |
Summary

FSG 66 / FSC 6610

DEMIL: D

DEMIL INT:

HMIC: N

Date Created: 9 Nov 1994

Unit Weight: 38.0 lbs

Unit Size: 31in x 17in x 14.5in

Unit Pack Cube: 4.422 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6610-01-398-8091 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
5050062-93 - Design Control Reference2 - Production ItemHONEYWELL INTL INC  0VWL8      
5050062-93 - Design Control Reference2 - Production ItemHONEYWELL INTL INC  55972    CAGE 55972  
5050062-93 - Design Control Reference9 - No Longer UsedHONEYWELL INTL INC  0VWL8      
CP-2280/ASQ-2195 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
CP-2280/ASQ-2195 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6610-01-398-8091 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666610013988091A3080053049X1DNAA09 Nov 1994
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6610

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Flight Instruments

013988091

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6610-01-398-8091

A30800

Federal Item Identification Guide (FIIG_4065)

53049

Item Naming Code (INC_4080)

9 Nov 1994

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG C - REFERENCE NUMBER | NSN 6610-01-398-8091 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ5050062-9  55972   CAGE/55972
395ZZ5050062-9  0VWL8  
524ZZCP-2280/ASQ-219  80058   CAGE/80058
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6610-01-398-8091 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TU627 Jan 1998
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

27 Jan 1998

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6610-01-398-8091 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK72DZ9AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6610-01-398-8091 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP41100038.0 lbs31in x 17in x 14.5in4.422 cu ft25.0 lbs22in x 8.8in x 7.5in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XNV00B17M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

38.0 lbs

Unit Pack Weight (UP_WT_5153)

31in x 17in x 14.5in

Unit Pack Size (UP_SZ_5154)

4.422 cu ft

Unit Pack Cube (UP_CU_5155)

25.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

22in x 8.8in x 7.5in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

NV

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

17

Special Marking Code (SP_MKG_CD_5169)


Reusable container

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6610-01-398-8091 Submit RFQ
MRCDecoded RequirementClear Text Reply
AXQJIntelligence Input MethodELECTRICAL
AWZJPower SourceEXTERNAL
ACURDirect Current Voltage Rating In Volts28.0
AAXXMounting TypeRACK
AJAFUnpackaged Unit Length19.65 INCHES NOMINAL
AJAGUnpackaged Unit Width7.50 INCHES NOMINAL
AJAHUnpackaged Unit Height7.62 INCHES NOMINAL
AGAVEnd Item IdentificationC141 ACFT
SUPPSupplementary FeaturesMANUFACTURERS NAME: PROCESSOR-DISPLAY,FLIGHT DATA
FTLDFunctional DescriptionFOCAL POINT FOR ALL COMMUNICATION WITH SYSTEM INSIDE AND OUTSIDE THE C-141 CONTROL DISPLAY SUBSYSTEM; COMMUNICATES WITH ALL INPUT SENSORS (RADIOS, GYROS, COMPASS SYSTEMS, 1553B MUX BUSSES) AND CONVERTS THE DATA FOR OUTPUT ON THE SERIAL DATA BUS TO THE SYSTEM DISPLAY UNITS; A REMOTE TERMINAL UNIT INTERFACING EXTENSIVE I/O FROM OTHER ACFT SYSTEMS WITH A DUAL MUX BUS STRUCTURE


Back to Top
Back to Top