Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
260-6P | 3 - Design Control Reference | 9 - No Longer Used | SIMPSON ELECTRIC COMPANY | 55026 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 000049536 | A310A0 | 00794 | X | K | A | P | A | 0 | 16 Jun 1972 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
WP01 | 1 Apr 2005 | |||||||||||||||||||||||||||||
YA01 | 1 Jan 2011 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 3 | JS | D | 260-6P | 55026 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Naval ICP, Mechanicsburg, PA 17055-0788
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 11 Mar 1993 | 6625012692463 | 16 Dec 1987 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JS | P | 72D | Z | Q | A | A | Q | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI | 1 |
Naval ICP, Mechanicsburg, PA 17055-0788
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
Unassigned. Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc
Extremely fragile items including delicate instruments.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Defense Logistics Agency
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 1 | 000 | 7.0 lbs | 10in x 9in x 6.5in | 0.338 cu ft | 4.0 lbs | 8in x 7in x 4.5in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | NA | X | EC | 00 | O |
Primary Inventory Control Activity (PICA)
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
No requirement.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPN | Accuracy In Percent | -1.5 TO 1.5 AT FULL SCALE SINGLE INDICATOR 6TH RANGE |
APPN | Accuracy In Percent | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 1ST RANGE |
APPN | Accuracy In Percent | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 3RD RANGE |
APPN | Accuracy In Percent | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 4TH RANGE |
APPN | Accuracy In Percent | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 5TH RANGE |
APPN | Accuracy In Percent | -3.0 TO 3.0 AT FULL SCALE SINGLE INDICATOR 2ND RANGE |
AQFY | Background Color | WHITE SINGLE INDICATOR ALL RANGES |
CTTD | Circuit Attachment Method And Quantity | 2 WIRE LEAD |
AACT | Circuit Current For Which Designed | DC |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR 1ST RANGE |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR 4TH RANGE |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR 5TH RANGE |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR 6TH RANGE |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR 3RD RANGE |
APMM | Dial Scale Marking Color | RED SINGLE INDICATOR 2ND RANGE |
AAPB | Dielectric Withstanding Voltage In Volts | 1000.0 |
AKYN | Furnished Items And Quantity | LEADS,TEST 2;BATTERIES 2;MANUAL 1 |
ANSY | Frequency Response Range | +0.020 TO 50.000 KILOHERTZ |
MATT | Material | PLASTIC PHENOLIC |
BHMW | Measurement Range | +0.0 TO 10.0 AMPERES, DC SINGLE INDICATOR 3RD RANGE |
BHMW | Measurement Range | +0.0 TO 1000.0 VOLTS, AC SINGLE INDICATOR 2ND RANGE |
BHMW | Measurement Range | +0.0 TO 1000.0 VOLTS, DC SINGLE INDICATOR 1ST RANGE |
BHMW | Measurement Range | +0.0 TO 20.0 MEGOHMS SINGLE INDICATOR 4TH RANGE |
BHMW | Measurement Range | +0.0 TO 50.0 MICROAMPERES, DC SINGLE INDICATOR 6TH RANGE |
BHMW | Measurement Range | +0.0 TO 500.0 MILLIAMPERES, DC SINGLE INDICATOR 5TH RANGE |
CTQL | Movement Suspension Method | TAUT BAND |
AQEC | Movement Type | MOVING COIL, PERMANENT MAGNET |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
ABFY | Overall Depth | 3.125 INCHES NOMINAL |
AMQY | Installation Design | HAND HELD |
AMKD | Indicator Type | DIAL W/POINTER |
AWZJ | Power Source | INTERNAL |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR 3RD RANGE |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR 5TH RANGE |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR 6TH RANGE |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR 1ST RANGE |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR 2ND RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR 1ST RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR 2ND RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR 3RD RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR 5TH RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR 6TH RANGE |
BHDC | Scale Graduation Type | NONLINEAR SINGLE INDICATOR 4TH RANGE |
BLSB | Scale Selection Method | SWITCH |
ANTG | Sensitivity Rating | 1000.0 OHMS PER VOLT |
ABHP | Overall Length | 7.000 INCHES NOMINAL |
ABMK | Overall Width | 5.250 INCHES NOMINAL |
ASSS | Pointer Color | RED SINGLE INDICATOR ALL RANGES |
FEAT | Special Features | OHMS ACCURACY IS PORM 1 DEG. OF ARC;MEASURES FROM NEG. 20 TO POS. 50 DECIBLES |
STYL | Style Designator | PORTABLE |