6625-00-009-4222

MULTIMETER


6625-00-009-4222 (6625000094222, 000094222)
Part Number (1 listing): 270-4
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT: 7

HMIC: P

Date Created: 28 Jul 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-009-4222 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
270-43 - Design Control Reference2 - Production ItemSIMPSON ELECTRIC COMPANY  55026    CAGE 55026  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-009-4222 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625000094222A310A000794X1APU028 Jul 1972
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

000094222

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-009-4222

A310A0

Federal Item Identification Guide (FIIG_4065)

00794

Item Naming Code (INC_4080)

28 Jul 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-009-4222 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZW011 Dec 1995
FGG4FEE400XD991 Sep 2000
ZG011 Jan 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

X

Nonconsumable Item Material Support Code (NIMSC_0076)


All other conditions.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-009-4222 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325SED270-4  55026   CAGE/55026
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-009-4222 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CTX01 Dec 1974
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-009-4222 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE738Z9AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-009-4222 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNN32VU1HEA0
DFFLZVU1UEA0
Code Definitions

N32

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Naval Inventory Control Point, Philadelphia, PA 19111-5098

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

U

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-009-4222 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-0.75 TO 0.75 AT FULL SCALE SINGLE INDICATOR 6TH RANGE
APPNAccuracy In Percent-1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR 4TH RANGE
APPNAccuracy In Percent-1.25 TO 1.25 AT FULL SCALE SINGLE INDICATOR 1ST RANGE
APPNAccuracy In Percent-1.25 TO 1.25 AT FULL SCALE SINGLE INDICATOR 3RD RANGE
APPNAccuracy In Percent-1.25 TO 1.25 AT FULL SCALE SINGLE INDICATOR 5TH RANGE
APPNAccuracy In Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR 2ND RANGE
AQFYBackground ColorWHITE SINGLE INDICATOR ALL RANGES
CTTDCircuit Attachment Method And Quantity2 WIRE LEAD
AACTCircuit Current For Which DesignedDC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR 3RD RANGE
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR 4TH RANGE
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR 1ST RANGE
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR 5TH RANGE
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR 6TH RANGE
APMMDial Scale Marking ColorRED SINGLE INDICATOR 2ND RANGE
AKYNFurnished Items And QuantityLEADS,TEST 2;BATTERIES 2;MANUAL 1
CBBLFeatures ProvidedPORTABLE
MATTMaterialPLASTIC
BHMWMeasurement Range+0.0 TO 50.0 MICROAMPERES, DC SINGLE INDICATOR 6TH RANGE
BHMWMeasurement Range+0.0 TO 500.0 MILLIAMPERES, DC SINGLE INDICATOR 5TH RANGE
BHMWMeasurement Range+0.0 TO 10.0 AMPERES, DC SINGLE INDICATOR 3RD RANGE
BHMWMeasurement Range+0.0 TO 1000.0 VOLTS, AC SINGLE INDICATOR 2ND RANGE
BHMWMeasurement Range+0.0 TO 1000.0 VOLTS, DC SINGLE INDICATOR 1ST RANGE
BHMWMeasurement Range+0.0 TO 20.0 MEGOHMS SINGLE INDICATOR 4TH RANGE
NHCFNuclear Hardness Critical FeatureNONHARDENED
ABFYOverall Depth3.125 INCHES NOMINAL
AMQYInstallation DesignHAND HELD
AMKDIndicator TypeDIAL W/POINTER
ASSSPointer ColorRED SINGLE INDICATOR ALL RANGES
BHDCScale Graduation TypeNONLINEAR SINGLE INDICATOR 4TH RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR 1ST RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR 2ND RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR 3RD RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR 5TH RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR 6TH RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 1ST RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 2ND RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 3RD RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 5TH RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 6TH RANGE
BLSBScale Selection MethodSWITCH
ABHPOverall Length7.000 INCHES NOMINAL
ABMKOverall Width5.250 INCHES NOMINAL
FEATSpecial FeaturesOHMS ACCURACY IS PORM 1 DEG. OF ARC;MEASURES FROM NEG. 20 TO POS. 50 DECIBLES
STYLStyle DesignatorPORTABLE


Back to Top