6625-00-043-2182

AMMETER


6625-00-043-2182 (6625000432182, 000432182)
Part Numbers (2 listings): 94-433-7 | AM2-0-80 |
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 6 May 1967

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-043-2182 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
94-433-71 - Source of Control Reference2 - Production ItemRAYTHEON TECHNICAL SERVICES COMPANY  3B150    CAGE 3B150  
AM2-0-803 - Design Control Reference9 - No Longer UsedAMMON INSTRUMENTS CORP  19068      
94-433-75 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  49956    CAGE 49956  
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-043-2182 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625000432182A310A016450X1APU6 May 1967
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

000432182

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-043-2182

A310A0

Federal Item Identification Guide (FIIG_4065)

16450

Item Naming Code (INC_4080)

6 May 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-043-2182 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-043-2182 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
125ZZ94-433-7  3B150   CAGE/3B150
3395SEDAM2-0-80  19068  
3595SEB94-433-7  49956   CAGE/49956
Code Definitions

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-043-2182 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX019 Jul 1973
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

19 Jul 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-043-2182 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEJ657Z9ABZW136740Z68820METERS-ELEC-PARTS
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

J

Less Than Carload (LCL_CD_2760)


100.2

657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

136740

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

68820

Uniform Freight Classification (UFC_CD_MODF_3040)

METERS-ELEC-PARTS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-043-2182 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-2.0/+2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
AQFYBackground ColorWHITE SINGLE INDICATOR SINGLE RANGE
CTTDCircuit Attachment Method And Quantity2 SOLDERLESS LUG
BHSXCircuit Construction TypeNONELECTRONIC
AACTCircuit Current For Which DesignedDC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
ADZCEnvironmental ProtectionDUSTPROOF
CBBLFeatures ProvidedZERO ADJUSTER
MATTMaterialPLASTIC
BHMWMeasurement Range+0.0/+80.0 AMPERES, DC SINGLE INDICATOR SINGLE RANGE
APSWMeter Body Diameter Behind Mounting Flange2.187 INCHES NOMINAL
APSTMeter Depth Behind Mounting Flange1.469 INCHES NOMINAL
ANRLMounting Arrangement StyleTHREE HOLE/STUD BOLT CIRCLE
AFFLMounting Bolt Circle Diameter2.440 INCHES NOMINAL
AXHRMounting Facility Type And Quantity3 THREADED STUD
CTQLMovement Suspension MethodJEWEL PIVOT BASE
AQECMovement TypeMOVING COIL, PERMANENT MAGNET
BLKZMounting Stud Diameter0.112 INCHES NOMINAL
ADAGMounting Stud Length0.438 INCHES NOMINAL
NHCFNuclear Hardness Critical FeatureNONHARDENED
ZZZVFsc Application DataTEST SET ELECTRONIC
AMQYInstallation DesignPANEL
AMKDIndicator TypeDIAL W/POINTER
ASSSPointer ColorBLACK SINGLE INDICATOR SINGLE RANGE
AWZJPower SourceEXTERNAL
ABWGScale Division Quantity80 SINGLE INDICATOR SINGLE RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR SINGLE RANGE
BLSBScale Selection MethodTERMINAL
ABKWOverall Height2.750 INCHES NOMINAL
ABHPOverall Length1.862 INCHES NOMINAL
ABMKOverall Width2.500 INCHES NOMINAL
APSNPanel For Which DesignedNONMAGNETIC
STYLStyle DesignatorRECTANGULAR FLUSH MTG
SFTTSurface TreatmentENAMEL SEMIGLOSS


Back to Top
Back to Top