Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SP1345-3 | 3 - Design Control Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | |
300-11328 | 5 - Replaced / Discontinued | 2 - Production Item | PHAOSTRON INSTRUMENT AND ELECTRONIC | 77221 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 000690687 | A310A0 | 16450 | X | 1 | A | P | A | 0 | 1 Jan 1963 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FGGX | FGTX | 0 | 0 | Z | TG | 1 Apr 2006 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 5 | TX | D | SP1345-3 | 80103 | |||||
1 | 5 | 2 | 6 | TX | D | 300-11328 | 77221 |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 5 Nov 1972 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
657 | Z | 9 | A | B | Z | W | 136740 | Z | 68820 | METERS-ELEC-PARTS |
Instruments, Electric Meter
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPN | Accuracy In Percent | -2.0/+2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
AQFY | Background Color | WHITE SINGLE INDICATOR SINGLE RANGE |
CTTD | Circuit Attachment Method And Quantity | 2 SOLDER LUG |
AACT | Circuit Current For Which Designed | DC |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR SINGLE RANGE |
BHMW | Measurement Range | +0.0 TO 8.0 AMPERES, DC SINGLE INDICATOR SINGLE RANGE |
APSW | Meter Body Diameter Behind Mounting Flange | 2.670 INCHES NOMINAL |
APST | Meter Depth Behind Mounting Flange | 1.062 INCHES NOMINAL |
ANRL | Mounting Arrangement Style | THREE HOLE/STUD BOLT CIRCLE |
AFFL | Mounting Bolt Circle Diameter | 3.160 INCHES NOMINAL |
ABTB | Mounting Hole Diameter | 0.150 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 3 UNTHREADED HOLE |
CTQL | Movement Suspension Method | JEWEL PIVOT BASE |
AQEC | Movement Type | MOVING COIL, PERMANENT MAGNET |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
ZZZV | Fsc Application Data | TEST SET,ELECT. EQUIP. |
AMQY | Installation Design | PANEL |
AMKD | Indicator Type | DIAL W/POINTER |
ASSS | Pointer Color | BLACK SINGLE INDICATOR SINGLE RANGE |
AARG | Reliability Indicator | NOT ESTABLISHED |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR SINGLE RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR SINGLE RANGE |
BLSB | Scale Selection Method | SWITCH |
ANTG | Sensitivity Rating | 75.0 MILLIVOLTS |
ADAV | Overall Diameter | 3.500 INCHES NOMINAL |
ABHP | Overall Length | 2.850 INCHES MAXIMUM |
APSN | Panel For Which Designed | MAGNETIC |
BHSX | Circuit Construction Type | UNABLE TO DECODE |
STYL | Style Designator | ROUND FLUSH MTG |