6625-00-071-8964

GENERATOR,SWEEP


6625-00-071-8964 (6625000718964, 000718964)
Part Number (1 listing): VS80WA1
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 20 Jul 1967

Unit Weight: 3,530.0 lbs

Unit Size:

Unit Pack Cube: 833.000 cu ft

Replacement NSN:

6625-01-079-0003

Replacement Date: 27 Dec 1982

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-071-8964 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
VS80WA13 - Design Control Reference2 - Production ItemTRILITHIC, INC.  23042      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-071-8964 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625000718964A3220000413XM9BPU020 Jul 1967
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

000718964

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-071-8964

A32200

Federal Item Identification Guide (FIIG_4065)

00413

Item Naming Code (INC_4080)

20 Jul 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-071-8964 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YJ011 Apr 1991
ZH011 Apr 1991
ZW011 Nov 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-071-8964 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324SEDVS80WA1  23042  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-071-8964 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX027 Dec 1982 6625010790003 26 Dec 1982
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

27 Dec 1982

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6625-01-079-0003

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

26 Dec 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-071-8964 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEP72DZQAAQW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

P

Less Than Carload (LCL_CD_2760)


77.5

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Q

Special Handling Code (SP_HDLG_CD_9240)


Unassigned. Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG W - PACKAGING DATA | NSN 6625-00-071-8964 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP5113,530.0 lbs833.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00JAGFXED0019O
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

3,530.0 lbs

Unit Pack Weight (UP_WT_5153)

833.000 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

JA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-3174, plastic sheet, polyolefin, 2 mil

GF

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


MIL-PRF-26514, Type I, Class 2, Grade B, flexible polyurethane foam, medium load range

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ED

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

19

Special Marking Code (SP_MKG_CD_5169)


Method 50 reusable container

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-071-8964 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHTHAttenuation In Decibels0.0
BHTHAttenuation In Decibels70.0
AGTABasic Shape StyleRECTANGULAR OR SQUARE
AQZFControl TypeLOCAL
BKFCExternal Ac Operating Voltage In Volts115.0 MINIMUM SINGLE VOLTAGE
BKFCExternal Ac Operating Voltage In Volts230.0 MAXIMUM SINGLE VOLTAGE
BHTDFrequency Adjustment TypeCONTINUOUS
BHTBFrequency Per Channel1.0 MEGAHERTZ MINIMUM OPERATING CHANNEL ERR-100
BHTBFrequency Per Channel1.2 GIGAHERTZ MAXIMUM OPERATING CHANNEL
BJBQOperating Ac Frequency In Hertz50.0 MINIMUM SINGLE VOLTAGE
BJBQOperating Ac Frequency In Hertz60.0 MAXIMUM SINGLE VOLTAGE
ALBMOperating Control MethodMANUAL
AKNAInclosure TypeENCASED
BHTNImpedance Rating Per Channel50.000 OHMS OPERATING CHANNEL
AMQYInstallation DesignRACK
BHTZSignal Data Type Per ChannelOPERATING CHANNEL SWEEP
ABKWOverall Height6.875 INCHES NOMINAL
ABHPOverall Length17.000 INCHES NOMINAL
ABMKOverall Width16.000 INCHES NOMINAL
FAAZPhaseSINGLE


Back to Top