6625-00-087-8251

VOLTMETER


6625-00-087-8251 (6625000878251, 000878251)
Part Number (1 listing): 50-171031RXRX
Summary

FSG 66 / FSC 6625

DEMIL: Q

DEMIL INT: 6

HMIC: P

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Export License Required:
Munitions List Item or Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-087-8251 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
50-171031RXRX3 - Design Control Reference2 - Production ItemAMETEK, INC.  97424    CAGE 97424  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-087-8251 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625000878251A310A016449X49QPU1 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

000878251

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-087-8251

A310A0

Federal Item Identification Guide (FIIG_4065)

16449

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-087-8251 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Apr 1991
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-087-8251 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3323TXD50-171031RXRX  97424   CAGE/97424
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-087-8251 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX05 Nov 1972
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Nov 1972

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-087-8251 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
J657Z5AHZW136740Z68820METERS-ELEC-PARTS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


J

Less Than Carload (LCL_CD_2760)


100.2

657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

136740

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

68820

Uniform Freight Classification (UFC_CD_MODF_3040)

METERS-ELEC-PARTS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-087-8251 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-2.0/+2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
AQFYBackground ColorWHITE SINGLE INDICATOR SINGLE RANGE
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length3.562 INCHES NOMINAL
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width4.000 INCHES NOMINAL
CTTDCircuit Attachment Method And Quantity2 BINDING POST
AACTCircuit Current For Which DesignedAC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
ANSYFrequency Response Range+0.000/+60.000 HERTZ
MATTMaterialPLASTIC
BHMWMeasurement Range+0.0/+300.0 VOLTS, AC SINGLE INDICATOR SINGLE RANGE
APSWMeter Body Diameter Behind Mounting Flange2.760 INCHES NOMINAL
APSTMeter Depth Behind Mounting Flange1.215 INCHES NOMINAL
ANRLMounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
AXHRMounting Facility Type And Quantity1 FLANGE
CTQLMovement Suspension MethodJEWEL PIVOT BASE
AQECMovement TypeMOVING IRON VANE
ADAGMounting Stud Length0.620 INCHES NOMINAL
AMQYInstallation DesignPANEL
AMKDIndicator TypeDIAL W/POINTER
ANTGSensitivity Rating54000.0 OHMS PER VOLT
FEATSpecial Features4 MTG HOLE/STUDS 0.138 IN. DIA
ABKWOverall Height4.846 INCHES NOMINAL
ABHPOverall Length1.465 INCHES NOMINAL
ABMKOverall Width4.408 INCHES NOMINAL
STYLStyle DesignatorRECTANGULAR FLUSH MTG


Back to Top
Back to Top