6625-00-090-6558

GENERATOR,PULSE


6625-00-090-6558 (6625000906558, 000906558)
Part Number (1 listing): 350
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 3 Dec 1972

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-090-6558 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3503 - Design Control Reference9 - No Longer UsedVELONEX  32570      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-090-6558 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625000906558A3220000411XM6BPU03 Dec 1972
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

000906558

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-090-6558

A32200

Federal Item Identification Guide (FIIG_4065)

00411

Item Naming Code (INC_4080)

3 Dec 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-090-6558 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-090-6558 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3394SED350  32570  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-090-6558 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-090-6558 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-090-6558 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHTJAverage Power Rating Per Channel22.0 KILOWATTS OUTPUT
BHTJAverage Power Rating Per Channel600.0 WATTS INPUT
AFSUAverage Life MeasurementNOT RATED
AGTABasic Shape StyleRECTANGULAR OR SQUARE
BJBPConnection Type And LocationRECEPTACLE, COAXIAL FRONT
AQZFControl TypeLOCAL
BKFCExternal Ac Operating Voltage In Volts115.0 NOMINAL SINGLE VOLTAGE
BJBQOperating Ac Frequency In Hertz50.0 MINIMUM SINGLE VOLTAGE
BJBQOperating Ac Frequency In Hertz60.0 MAXIMUM SINGLE VOLTAGE
ALBMOperating Control MethodMANUAL
BJBJOutput Wave ShapePULSE, VARIABLE WIDTH
BHTNImpedance Rating Per Channel200.000 OHMS OUTPUT CHANNEL
BJBLIndicator Device Type And Quantity1 METER
AKNAInclosure TypeENCASED
AMQYInstallation DesignTOP OF CABINET/COUNTER
BHTSPolarity Per ChannelNEGATIVE OUTPUT CHANNEL
BHTTPulse Repetition Rate Per Channel100.000 KILOPULSES PER SECOND MAXIMUM OUTPUT CHANNEL
BHTTPulse Repetition Rate Per Channel3.000 PULSES PER SECOND MINIMUM OUTPUT CHANNEL
BHTQPulse Rise Time Per Channel30.000 NANOSECONDS NOMINAL OUTPUT CHANNEL
BHTRPulse Decay Time Per Channel50.000 NANOSECONDS NOMINAL OUTPUT CHANNEL
BHTPPulse Duration Per Channel100.000 NANOSECONDS MINIMUM OUTPUT CHANNEL
BHTPPulse Duration Per Channel300.000 MICROSECONDS MAXIMUM OUTPUT CHANNEL
BHTZSignal Data Type Per ChannelOUTPUT CHANNEL PULSE
BHTKSignal Voltage Rating Per Channel0.000 VOLTS MINIMUM OUTPUT
BHTKSignal Voltage Rating Per Channel2.100 KILOVOLTS MAXIMUM OUTPUT
ABKWOverall Height13.000 INCHES NOMINAL
ABHPOverall Length19.750 INCHES NOMINAL
ABMKOverall Width18.000 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesOVERLOAD PROTECTION W/RESET


Back to Top