6625-00-102-4312

METER,ARBITRARY SCALE


6625-00-102-4312 (6625001024312, 001024312)
Part Number (1 listing): 579R014H03
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 5 Jun 1968

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-102-4312 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
579R014H033 - Design Control Reference9 - No Longer UsedSOLARTRON ELECTRONICS INC  65092    CAGE 65092  
579R014H037 - Vendor Item Drawing Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-102-4312 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625001024312A310A016476X1APA05 Jun 1968
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

001024312

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-102-4312

A310A0

Federal Item Identification Guide (FIIG_4065)

16476

Item Naming Code (INC_4080)

5 Jun 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-102-4312 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND00ZKEKE1 Apr 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-102-4312 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3395KED579R014H03  65092   CAGE/65092
3721KED579R014H03  97942   CAGE/97942
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-102-4312 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX03 Mar 1978
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Mar 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-102-4312 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE657Z9AHZW136740Z68820METERS-ELEC-PARTS
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

136740

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

68820

Uniform Freight Classification (UFC_CD_MODF_3040)

METERS-ELEC-PARTS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-102-4312 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSXU1EA0
DSSMSXU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-102-4312 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES
AQFYBackground ColorWHITE SINGLE INDICATOR ALL RANGES
CTTDCircuit Attachment Method And Quantity2 THREADED STUD
AACTCircuit Current For Which DesignedDC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR ALL RANGES
AAPBDielectric Withstanding Voltage In Volts3000.0
AKYNFurnished Items And QuantityNUT 7; LOCKWASHER 5; SEAL 1
ADZCEnvironmental ProtectionAIRTIGHT AND DUST RESISTANT AND FUNGUS RESISTANT AND HEAT RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND WATER RESISTANT
CBBLFeatures ProvidedMAGNETIC SHIELD AND ZERO ADJUSTER
MATTMaterialSTEEL
APSWMeter Body Diameter Behind Mounting Flange2.754 INCHES MAXIMUM
APSTMeter Depth Behind Mounting Flange1.378 INCHES MAXIMUM
ANRLMounting Arrangement StyleTHREE HOLE/STUD BOLT CIRCLE
AFFLMounting Bolt Circle Diameter3.194 INCHES NOMINAL
AXHRMounting Facility Type And Quantity3 SCREW AND 3 UNTHREADED HOLE
ABTBMounting Hole Diameter0.150 INCHES NOMINAL
CTQLMovement Suspension MethodJEWEL PIVOT BASE
AQECMovement TypeMOVING COIL, PERMANENT MAGNET
NHCFNuclear Hardness Critical FeatureNONHARDENED
ZZZVFsc Application DataTEST SET,ELECT. EQUIP.
AMQYInstallation DesignPANEL
AMKDIndicator TypeDIAL W/POINTER
ASSSPointer ColorBLACK SINGLE INDICATOR ALL RANGES
ABWGScale Division Quantity10 SINGLE INDICATOR 2ND RANGE
ABWGScale Division Quantity15 SINGLE INDICATOR 3RD RANGE
ABWGScale Division Quantity50 SINGLE INDICATOR 1ST RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR ALL RANGES
ASTWScale MarkingTOP SCALE,-25; -20; -15; -10; -5; 0; +5; +10; +15; +20; +25; MIDDLE SCALE,15; 20; 25; BOTTOM SCALE,.15; .20; .25; .30; UNDER TOP SCALE,DEGREES; UNDER MIDDLE SCALE,PERCENT; BOTTOM SCALE,INDEX
ANTGSensitivity Rating50.0 MICROAMPERES
ADAVOverall Diameter3.496 INCHES MAXIMUM
ABHPOverall Length2.571 INCHES MAXIMUM
FEATSpecial FeaturesRUGGEDIZED
MARKSpecial MarkingsON BACK,SEALED DO NOT OPEN
SPCLSpecial Test FeaturesCOMPLIES WITH MIL-M-10304
STYLStyle DesignatorROUND FLUSH MTG
SFTTSurface TreatmentCHROMATE


Back to Top
Back to Top