Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
R647A | 3 - Design Control Reference | 2 - Production Item | TEKTRONIX, INC. | 80009 | |
11293369-2 | 5 - Replaced / Discontinued | 2 - Production Item | BALLISTIC MISSILE DEFENSE SYSTEMS | 17773 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 001058197 | T320-G | 00357 | X | M | 3 | A | P | A | 0 | 3 Jul 1968 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 23 Jul 1986 | 6625005836578 | 3 Apr 1983 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | P | 72D | Z | Q | A | A | Q | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI | 1 |
Central Intelligence Agency, Washington, DC 20505
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
Unassigned. Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc
Extremely fragile items including delicate instruments.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 51 | 1 | 8,410.0 lbs | 1,063.000 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NW | 00 | 00 | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type IV, horizontal star cushioning in reusable box.
No requirement.
No special marking
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKYD | Accessory Components And Quantity | CABLE/PLUG 1,FILTER 1,GRCITICULE LIGHT INSERT2,PATCH CORD 3,PROBE 2 |
BDJD | Accuracy Range In Percent | -0.1 TO 0.1 |
BHDD | Amplifier Deflection Sensitivity Provision | PROVIDED |
BHDT | Amplifier Input Impedance Rating Provision | NOT PROVIDED |
BHDZ | Amplitude Calibrating Voltage Waveform | SQUARE WAVE |
ATES | Beam Quantity | 1 |
BHFT | Camera Recording Device Accommodation | NOT PROVIDED |
BHFF | Calibrated Screen Scale | INCLUDED |
BHFB | Calibrating Peak To Peak Amplitude | 0.2 MILLIVOLTS MINIMUM AND 100.0 VOLTS MAXIMUM |
ACDC | Current Type | AC |
BGSD | Expanded Sweep | NOT PROVIDED |
ACZB | Frequency Rating | 45.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM |
BHDP | Frequency Response Rating | PROVIDED |
BGQM | Generator Driven Feature | INCLUDED |
AWEC | Graduation Interval | RULED IN 1 CM DIV BOTH AXIS,FURTHER MARKED IN 2 MM INCREMENTS |
BHDG | Horizontal Deflection Sensitivity Voltage Rating | 125.0 MILLIVOLTS CW MINOR AND 300.0 MILLIVOLTS MAXIMUM RMS PER CENTIMETER |
BHFC | Measurement Range Quantity | 18 |
BHFD | Measurement Range Steps | 0.2 MV TO 100.0 V /1-2-5 SEQUENCE |
AXGY | Mounting Method | CABINET W/COMPLETE HARDWARE FOR RACK |
NTRD | Entry Date | 88-10-01 |
FCLS | Functional Classification | AA-3.2 |
BHDH | Input Intensity Modulation Feature | PROVIDED |
BHFS | Plug In Unit Function And Quantity | DUAL TRACE AMPLIFIER 1,DELAYED SWEEP TIME BASE 1 |
BHDL | Plate Direct Connection Deflection Sensitivity Provision | NOT PROVIDED |
BGQK | Screen Size | 3.000 |
BGQQ | Single Trigger Sweep Duration | 0.1 MICROSECONDS MINIMUM AND 5.0 SECONDS MAXIMUM |
ABKW | Overall Height | 7.000 INCHES NOMINAL |
ABHP | Overall Length | 19.000 INCHES NOMINAL |
ABMK | Overall Width | 19.000 INCHES NOMINAL |
BHFH | Trace Storage Tube | NOT INCLUDED |
BGSB | Trigger Sweep Polarity Switch | NOT INCLUDED |
BGRZ | Trigger Sweep Voltage Amplitude Rating | 125.0 MILLIVOLTS MINIMUM AND 250.0 MILLIVOLTS MAXIMUM |
BHDF | Vertical Deflection Sensitivity Voltage Rating | 10.0 MILLIVOLTS MINIMUM RMS PER CENTIMETER AND 20.0 VOLTS MAXIMUM RMS PER CENTIMETER |
AMSE | Voltage Rating | 115.0 VOLTS NOMINAL |
BHDQ | X-Axis Frequency Response Rating | 3.0 MEGAHERTZ NOMINAL |
BHDR | Y-Axis Frequency Response Rating | 1.0 MEGAHERTZ NOMINAL |
BGQN | Sweep Circuit Type | HORIZONTAL |
BGQL | Sweep Circuits | INCLUDED |
BGQP | Sweep Frequency Range | +20.000/+100.000 MEGAHERTZ |