Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2000 | 3 - Design Control Reference | 9 - No Longer Used | TRI-PHENIX ELECTRONICS | 52800 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 001151583 | A32200 | 00411 | X | M | 9 | B | P | U | 0 | 13 Sep 1968 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 5 | SE | D | 2000 | 52800 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 18 Feb 2003 | 6625012665934 | 18 Feb 2003 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | P | 738 | 3 | 9 | A | H | Q | J | 061700 | X | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
77.5
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Extremely fragile items including delicate instruments.
100.2
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 51 | 1 | 1,200.0 lbs | 145.000 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | JA | NA | X | ED | 00 | 19 | O |
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
A-A-3174, plastic sheet, polyolefin, 2 mil
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Method 50 reusable container
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | RECTANGULAR OR SQUARE |
BJBP | Connection Type And Location | RECEPTACLE, COAXIAL FRONT AND INTEGRAL CORD W/POWER PLUG REAR |
BJBW | Connection Contact Type And Quantity | 4 RECEPTACLE, COAXIAL INTERNAL AND 3 RECEPTACLE, COAXIAL EXTERNAL |
AQZF | Control Type | LOCAL |
NTRD | Entry Date | 90-10-01 |
ADZC | Environmental Protection | DUSTPROOF |
BKFC | External Ac Operating Voltage In Volts | 115.0 MINIMUM SINGLE VOLTAGE |
BKFC | External Ac Operating Voltage In Volts | 230.0 MAXIMUM SINGLE VOLTAGE |
BHTD | Frequency Adjustment Type | STEPPED |
BHTB | Frequency Per Channel | 10.0 HERTZ MINIMUM OPERATING CHANNEL ERR-100 |
BHTB | Frequency Per Channel | 20.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL ERR-100 |
FCLS | Functional Classification | BB-1.1 |
BHSX | Circuit Construction Type | SOLID STATE |
BJBQ | Operating Ac Frequency In Hertz | 400.0 MAXIMUM SINGLE VOLTAGE |
BJBQ | Operating Ac Frequency In Hertz | 50.0 MINIMUM SINGLE VOLTAGE |
ALBM | Operating Control Method | MANUAL |
BJBJ | Output Wave Shape | PULSE, VARIABLE WIDTH |
BHTN | Impedance Rating Per Channel | 50.000 OHMS OPERATING CHANNEL |
BJBL | Indicator Device Type And Quantity | 1 LIGHT |
AKNA | Inclosure Type | ENCASED |
BHTF | Individual Step Frequency | 10.0 HERTZ AND 1.0 KILOHERTZ AND 10.0 KILOHERTZ AND 100.0 KILOHERTZ AND 1.0 MEGAHERTZ AND 10.0 MEGAHERTZ |
AMQY | Installation Design | PORTABLE |
BHTS | Polarity Per Channel | NEGATIVE OPERATING CHANNEL ERR-100 |
BHTS | Polarity Per Channel | POSITIVE OPERATING CHANNEL ERR-100 |
BHTQ | Pulse Rise Time Per Channel | 5.000 NANOSECONDS NOMINAL OPERATING CHANNEL |
BHTR | Pulse Decay Time Per Channel | 5.000 NANOSECONDS NOMINAL OPERATING CHANNEL |
BHTY | Pulse Modulation Type Per Channel | AMPLITUDE OPERATING CHANNEL |
BHTZ | Signal Data Type Per Channel | OPERATING CHANNEL PULSE DELAY ERR-100 |
BHTZ | Signal Data Type Per Channel | OPERATING CHANNEL PULSE, AMPLITUDE ERR-100 |
BHTK | Signal Voltage Rating Per Channel | 0.000 VOLTS INPUT PRESET |
BHTK | Signal Voltage Rating Per Channel | 15.000 VOLTS INTERSTAGE PRESET |
ABKW | Overall Height | 4.000 INCHES NOMINAL |
ABHP | Overall Length | 9.500 INCHES NOMINAL |
ABMK | Overall Width | 8.500 INCHES NOMINAL |
FAAZ | Phase | SINGLE |
FAAZ | Phase | TWO |