Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
S1203503 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 97942 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 001661050 | A310A0 | 16450 | X | 1 | A | P | A | 0 | 1 Jan 1963 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF | ||||||||||||||||||||||||||||||
ZR | ||||||||||||||||||||||||||||||
ZS | ||||||||||||||||||||||||||||||
ZU | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
FGGX | 5 | U | Z | TG | 1 Jul 2005 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The cost to the Government to breakout this part and acquire it competitively has been determined to exceed the projected savings over the life span of the part. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 5 | 48 | D | S1203503 | 97942 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Federal Aviation Administration, Oklahoma City, OK 73125
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
657 | Z | 9 | A | H | Z | W | 136740 | Z | 68820 | METERS-ELEC-PARTS |
Instruments, Electric Meter
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPN | Accuracy In Percent | -2.0/+2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
AQFY | Background Color | WHITE SINGLE INDICATOR SINGLE RANGE |
CTTD | Circuit Attachment Method And Quantity | 2 THREADED STUD |
AACT | Circuit Current For Which Designed | DC |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR SINGLE RANGE |
AAPB | Dielectric Withstanding Voltage In Volts | 3000.0 |
ZZZV | Fsc Application Data | TEST SET ELECTRONIC |
MATT | Material | PLASTIC |
BHMW | Measurement Range | +0.0/+1.0 MILLIAMPERES, DC SINGLE INDICATOR SINGLE RANGE |
APSW | Meter Body Diameter Behind Mounting Flange | 2.210 INCHES NOMINAL |
APST | Meter Depth Behind Mounting Flange | 2.250 INCHES MAXIMUM |
ANRL | Mounting Arrangement Style | THREE HOLE/STUD BOLT CIRCLE |
AFFL | Mounting Bolt Circle Diameter | 2.440 INCHES NOMINAL |
ABTB | Mounting Hole Diameter | 0.125 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 3 UNTHREADED HOLE |
CTQL | Movement Suspension Method | METAL PIVOT BASE |
AQEC | Movement Type | MOVING COIL, PERMANENT MAGNET |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
AMQY | Installation Design | PANEL |
AMKD | Indicator Type | DIAL W/POINTER |
ASSS | Pointer Color | BLACK SINGLE INDICATOR SINGLE RANGE |
ABWG | Scale Division Quantity | 6 SINGLE INDICATOR SINGLE RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR SINGLE RANGE |
ANTG | Sensitivity Rating | 150.0 MILLIVOLTS |
ADAV | Overall Diameter | 2.695 INCHES NOMINAL |
ABHP | Overall Length | 2.650 INCHES MAXIMUM |
APSN | Panel For Which Designed | UNABLE TO DECODE |
BHSX | Circuit Construction Type | UNABLE TO DECODE |
STYL | Style Designator | ROUND FLUSH MTG |