6625-00-500-6640

MULTIMETER


6625-00-500-6640 (6625005006640, 005006640)
Part Number (1 listing): DM501
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 6 Jul 1974

Unit Weight: 7.0 lbs

Unit Size: 21in x 15in x 9.5in

Unit Pack Cube: 1.731 cu ft

Replacement NSN:

6625-01-298-9045

Replacement Date: 14 Feb 2003

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-500-6640 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
DM5013 - Design Control Reference2 - Production ItemTEKTRONIX, INC.  80009    CAGE 80009  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-500-6640 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625005006640A310A000794X43APAA06 Jul 1974
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

005006640

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-500-6640

A310A0

Federal Item Identification Guide (FIIG_4065)

00794

Item Naming Code (INC_4080)

6 Jul 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-500-6640 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZT011 Apr 1991
ZR011 Jul 1997
FGG4FEE400FDFR1 Sep 2000
YA011 Jan 2002
ZW011 Nov 2005
ZU011 Apr 2008
YK011 Feb 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-500-6640 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4324SBADM501  80009   CAGE/80009
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-500-6640 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX01TX014 Feb 2003 6625012989045 14 Feb 2003
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

14 Feb 2003

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6625-01-298-9045

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

14 Feb 2003

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-500-6640 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SJM738Z9AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SJ

Originating Activity Code (ORIG_ACTY_CD_4210)


Air Force Cryptological Support Center, San Antonio, TX 78243-5000

M

Less Than Carload (LCL_CD_2760)


85

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-500-6640 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZVU1SEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG W - PACKAGING DATA | NSN 6625-00-500-6640 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP5110007.0 lbs21in x 15in x 9.5in1.731 cu ft2.0 lbs12in x 5in x 2.5in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XNV00B03M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

7.0 lbs

Unit Pack Weight (UP_WT_5153)

21in x 15in x 9.5in

Unit Pack Size (UP_SZ_5154)

1.731 cu ft

Unit Pack Cube (UP_CU_5155)

2.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

12in x 5in x 2.5in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

NV

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

03

Special Marking Code (SP_MKG_CD_5169)


Mehod 50

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-500-6640 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQYInstallation DesignBENCH
AMKDIndicator TypeDIGITAL DISPLAY
BFQPDisplay Digit Quantity4-1/2
FAAZPhaseSINGLE
STYLStyle DesignatorROUND SURFACE MTG
FEATSpecial FeaturesINCLUDES ONE PAIR OF TEST LEADS 003-0120-00, TEMPERATURE PROBE P6601; AND 010-6601-01 INSTRUCTION MANUAL; .05 PCT DC VOLTAGE ACCURACY; 7 FUNCTIONS INCLUDING TEMP AND DB; TRUE RMS CAPABILITY; MEASURES DC VOLTAGE TO 1000V; AC VOLTAGE TO 500 V; BOTH AC & DC CURRENT TO 2 AMPS; TRUE RMS VOLTAGES; AND RESISTANCE TO 20 MEGOHMS
ZZZVFsc Application DataTEST SETS,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED


Back to Top
Back to Top