6625-00-643-1740

OSCILLOSCOPE


6625-00-643-1740 (6625006431740, 006431740)
Part Numbers (2 listings): 0S8U | 902-110 |
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1961

Unit Weight: 1,850.0 lbs

Unit Size:

Unit Pack Cube: 149.000 cu ft

Replacement NSN:

6625-00-649-9284

Replacement Date: 8 Oct 1965

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-643-1740 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0S8U3 - Design Control Reference2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
902-1105 - Replaced / Discontinued2 - Production ItemHICKOK INCORPORATED  28569    CAGE 28569  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-643-1740 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625006431740T320-G00357XM6APAA01 Jan 1961
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

006431740

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-643-1740

T320-G

Federal Item Identification Guide (FIIG_4065)

00357

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-643-1740 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
ZP011 Apr 1991
ZU011 Apr 1991
ZR011 Jul 1997
WB011 Feb 2005
ZW011 Nov 2005
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-643-1740 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX08 Oct 1965 6625006499284 26 Feb 1983
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Oct 1965

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6625-00-649-9284

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

26 Feb 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-643-1740 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P653ZQAAQW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

653

Water Commodity Code (WRT_CMDTY_CD_9275)


Musical Instruments

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Q

Special Handling Code (SP_HDLG_CD_9240)


Unassigned. Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-643-1740 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNN35VU1HEA0
Code Definitions

N35

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 6625-00-643-1740 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP5111,850.0 lbs149.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00JAZZ0ED0019O
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

1,850.0 lbs

Unit Pack Weight (UP_WT_5153)

149.000 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

JA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-3174, plastic sheet, polyolefin, 2 mil

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

ED

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

19

Special Marking Code (SP_MKG_CD_5169)


Method 50 reusable container

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-643-1740 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And Quantity1 CY-845U CASE,1 CG-656V TEST LEAD 4 FT,1 CG-656V TEST LEAD 1 FT,1 HOOD
BHDDAmplifier Deflection Sensitivity ProvisionNOT PROVIDED
BHDTAmplifier Input Impedance Rating ProvisionPROVIDED
ATESBeam Quantity1
BHFFCalibrated Screen ScaleNOT INCLUDED
BHFTCamera Recording Device AccommodationNOT PROVIDED
ACDCCurrent TypeAC
BHDNDirect Connection Horizontal Deflection Sensitivity Voltage Rating28.0 VOLTS NOMINAL RMS PER INCH
BHDMDirect Connection Vertical Deflection Sensitivity Voltage Rating22.0 VOLTS ANY ACCEPTABLE OUTSIDE DIAMETER
BGSDExpanded SweepNOT PROVIDED
BHDPFrequency Response RatingPROVIDED
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 1600.0 HERTZ MAXIMUM
BGQMGenerator Driven FeatureNOT INCLUDED
BHDHInput Intensity Modulation FeatureNOT PROVIDED
BHDLPlate Direct Connection Deflection Sensitivity ProvisionPROVIDED
BGQKScreen Size3 IN.
ABKWOverall Height9.000 INCHES NOMINAL
ABHPOverall Length13.500 INCHES NOMINAL
ABMKOverall Width6.000 INCHES NOMINAL
FAAZPhaseSINGLE
BHFHTrace Storage TubeNOT INCLUDED
BGSBTrigger Sweep Polarity SwitchNOT INCLUDED
AMSEVoltage Rating105.0 VOLTS MINIMUM AND 125.0 VOLTS MAXIMUM
BHDQX-Axis Frequency Response Rating5.0 HERTZ MINIMUM AND 2000000.0 HERTZ MAXIMUM
BHDWX-Axis Input Impedance Rating1.5 MEGOHMS NOMINAL
BHDRY-Axis Frequency Response Rating25.0 HERTZ MINIMUM AND 100000.0 HERTZ MAXIMUM
BHDXY-Axis Input Impedance Rating2.0 MEGOHMS NOMINAL
BGQLSweep CircuitsINCLUDED
BGQPSweep Frequency Range+3.000/+50000.000 HERTZ


Back to Top
Back to Top