6625-00-729-6720

AMMETER


6625-00-729-6720 (6625007296720, 007296720)
Part Number (1 listing): 559C12-2
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-729-6720 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
559C12-23 - Design Control Reference2 - Production ItemCARDWELL CONDENSER CORP  94033    CAGE 94033  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-729-6720 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625007296720A310A016450XM9APU1 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

007296720

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-729-6720

A310A0

Federal Item Identification Guide (FIIG_4065)

16450

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-729-6720 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
DGX15HTX1 Apr 2006
Code Definitions

5

Acquisition Method Code (AMC_2871)


Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

TX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-729-6720 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325TX559C12-2  94033   CAGE/94033
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-729-6720 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
657Z9AHZW136740Z68820METERS-ELEC-PARTS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

136740

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

68820

Uniform Freight Classification (UFC_CD_MODF_3040)

METERS-ELEC-PARTS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-729-6720 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-729-6720 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-3.0/+3.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
AQFYBackground ColorWHITE SINGLE INDICATOR SINGLE RANGE
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.312 INCHES NOMINAL
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.312 INCHES NOMINAL
CTTDCircuit Attachment Method And Quantity2 SOLDERLESS LUG
AACTCircuit Current For Which DesignedDC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
CBBLFeatures ProvidedMAGNETIC SHIELD
BHMWMeasurement Range-20.0/+20.0 MILLIAMPERES, DC SINGLE INDICATOR SINGLE RANGE
APSTMeter Depth Behind Mounting Flange1.000 INCHES NOMINAL
APSWMeter Body Diameter Behind Mounting Flange1.510 INCHES NOMINAL
ANRLMounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
AXHRMounting Facility Type And Quantity4 THREADED STUD
BLKZMounting Stud Diameter0.112 INCHES NOMINAL
AQECMovement TypeMOVING IRON VANE
AMQYInstallation DesignPANEL
ABWGScale Division Quantity20 SINGLE INDICATOR SINGLE RANGE
ANTGSensitivity Rating100.0 MILLIVOLTS
ABKWOverall Height1.766 INCHES NOMINAL
ABHPOverall Length1.250 INCHES NOMINAL
ABMKOverall Width1.766 INCHES NOMINAL
MARKSpecial MarkingsDEGREES TILT
STYLStyle DesignatorRECTANGULAR FLUSH MTG


Back to Top