Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
TV7DU | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MILT12424 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
TV7DU | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
1091400B9-1 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 92755 | ![]() |
TV7DU | C - Advisory Reference | 1 - Incomplete Part Number | FORWAY INDUSTRIES INC | 00641 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 008200064 | T228-C | 00797 | N | 1 | B | P | A | 0 | 1 Jan 1962 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | 1 | G | A | E | CL | 99 | AM | AZ | 1 Apr 1991 | |||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
YA01 | 1 Jan 2011 | |||||||||||||||||||||||||||||
YY01 | 1 Feb 2015 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
An activitiy within the Army is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | C | 1 | 6 | TX | D | TV7DU | 00641 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 4 Aug 1999 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FF | W | 658 | Z | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
Code FF denotes special factors or conditions in an item description which have an effect on the ratings or charges; therefore, the item description should be read carefully to ensure that such special factors or conditions can be included as a part of the bill of lading description.
Rating Variable
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Communication/electronic equipment and parts
1
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Unclassified
Department of the Army
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 51 | 1 | 3,370.0 lbs | 359.000 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NV | 00 | 00 | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.
No requirement.
No special marking
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADTV | Case Material | ALUMINUM |
ADTY | Case Surface Treatment | ENAMEL |
AKYN | Furnished Items And Quantity | 3 TUBE SOCKET ADAPTERS,2 PIN STRAIGHTENERS,2 TEST LEADS,2 BOOK INSTRUCTION |
AQYG | Filament Voltage Rating In Volts | +0.600/+117.000 |
ZZZT | Nondefinitive Spec/Std Data | TV-7D/U TYPE |
APHE | Operation Method | DYNAMIC MUTUAL CONDUCTANCE |
ALSF | Internal Battery Accommodation | NOT INCLUDED |
AMQY | Installation Design | PORTABLE |
ABWC | Scale Unit Of Measure Inscription | VOLTS |
ABKW | Overall Height | 6.310 INCHES NOMINAL |
ABHP | Overall Length | 15.600 INCHES NOMINAL |
ABMK | Overall Width | 10.700 INCHES NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | TEST SET ELECTRON TUBE: TV-7/U |
FAAZ | Phase | SINGLE |