6625-00-828-5810

TEST SET,ARMATURE


6625-00-828-5810 (6625008285810, 008285810)
Part Numbers (6 listings): 2501A | TS965U | MILT594 | TYPEA | SIM | 2501 |
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 1 Jan 1962

Unit Weight: 1,350.0 lbs

Unit Size:

Unit Pack Cube: 57.000 cu ft

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-00-828-5810 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2501A3 - Design Control Reference2 - Production ItemCROWN INDUSTRIAL PRODUCTS CO  92381      
TS965U3 - Design Control Reference2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
MILT5944 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
TYPEA4 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
SIM5 - Replaced / Discontinued2 - Production ItemCROWN INDUSTRIAL PRODUCTS CO  92381      
25015 - Replaced / Discontinued2 - Production ItemCROWN INDUSTRIAL PRODUCTS CO  92381      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6625-00-828-5810 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625008285810T228-B00717X1BPA01 Jan 1962
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

008285810

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-00-828-5810

T228-B

Federal Item Identification Guide (FIIG_4065)

00717

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-00-828-5810 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE011 Apr 1991
ZH011 Apr 1991
YW011 Mar 1995
ZU011 Aug 1995
YA011 Oct 2000
FGG4F5BD1GXD991 Jul 2003
NAGSNSDD1G3DJAHD1 Jul 2003
A3901G3DTBBFBS1 Sep 2004
ZW011 Nov 2005
YD011 Sep 2016
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.

X

Nonconsumable Item Material Support Code (NIMSC_0076)


All other conditions.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

3

Nonconsumable Item Material Support Code (NIMSC_0076)


End Item Primary Inventory Control Activity. This code identifies SICA managed end items or equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance, if required, to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions for SICA activities. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.

JADSOR

Depot Source of Repair Codes (DSOR_0903)


Fleet Readiness Center South East (FRC-SE), Jacksonville FL

TBDSOR

Depot Source of Repair Codes (DSOR_0903)


Tobyhanna Army Depot (TYAD), PA

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

BF

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000

BS

Supplementary Receivers (SUPPLM_RCVR_2534)


USAMC Data Management Center, Redstone Arsenal, AL 35898-5239


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-00-828-5810 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324SED2501A  92381  
3413TXDMILT594  81349   CAGE/81349
3413TXDTYPEA  81349   CAGE/81349
3525SED2501  92381  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-00-828-5810 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-00-828-5810 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
E73839AHQW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


E

Less Than Carload (LCL_CD_2760)


175

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-00-828-5810 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAB64AU1EA0
DFFLZAU1UEA0
DNNRPZU1MEA0
Code Definitions

B64

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Aviation and Missile Command, ATTN: AMSMI-LC-MM-C Redstone Arsenal, AL 35898-5230

A

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-REGULATED (Service/Agency use only.) Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

U

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

M

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: Medium Demand Velocity Items (Consumables)

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 6625-00-828-5810 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP3311,350.0 lbs57.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXEC0000O
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

33

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Greaseproof-waterproof bag, Sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

1,350.0 lbs

Unit Pack Weight (UP_WT_5153)

57.000 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

EC

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-00-828-5810 Submit RFQ
MRCDecoded RequirementClear Text Reply
AQYAArmature Diameter Accommodated1.500 INCHES MINIMUM AND 8.000 INCHES MAXIMUM
ACDCCurrent TypeAC
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
AFLYFunctioning Signal MethodAUDIBLE AND VISUAL
ABKWOverall Height4.750 INCHES NOMINAL
ABHPOverall Length9.500 INCHES NOMINAL
ABMKOverall Width5.750 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesMETERMOUNTED IN TOP TO INDIVATE CURRENT PASSING THRU ARMATURE
ELECVoltage In Volts115.0


Back to Top
Back to Top