Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8040A01 | 3 - Design Control Reference | 2 - Production Item | FLUKE CORPORATION | 89536 | ![]() |
ME6694 | 5 - Replaced / Discontinued | 2 - Production Item | KONINKLYKE LANDMACHTDM PRODUCTGROEP | H0G30 | ![]() |
ME6694 | 5 - Replaced / Discontinued | 2 - Production Item | KONINKLYKE LANDMACHT DMKL-MVA 2 | H1200 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 010544949 | A310A0 | 00794 | X | M | 6 | Q | P | A | A | 0 | 21 Jan 1978 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
FGG4 | FEE4 | 3 | C | F | D | FR | 1 Jan 2001 | |||||||||||||||||||||||
ZR01 | 1 Dec 2007 | |||||||||||||||||||||||||||||
YB01 | 1 Sep 2009 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Air Force is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 5 | 2 | 5 | ZN | C | ME6694 | H0G30 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Netherlands
The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 0 | 26 Aug 1983 | 6625010364972 | 28 Aug 1983 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | P | 72D | 3 | 9 | A | H | Z | A | 061700 | A | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
400
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Pilferage - Pilferage controls may be designated by the coding activity to items coded U (Unclassified) by recording the item to J.
1
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 51 | 1 | 000 | 7.9 lbs | 12.5in x 12.5in x 14.5in | 1.311 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NR | 00 | B | 00 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type I, vertical star cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
No special marking
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPB | Dielectric Withstanding Voltage In Volts | 1100.0 |
AKYN | Furnished Items And Quantity | RECHARGEABLE BATTERY 4,BATTERY CHARGER/ELEMINATOR 1,TEST LEAD 2 |
CBBL | Features Provided | ELECTRICAL OVERLOAD PROTECTION |
ACZB | Frequency Rating | 48.000 HERTZ MINIMUM AND 66.000 HERTZ MAXIMUM |
BHMW | Measurement Range | +0.0/+1.9 KILOHMS SINGLE INDICATOR 1ST RANGE |
BHMW | Measurement Range | +0.0/+1.9 MILLIAMPERES, AC SINGLE INDICATOR 8TH RANGE |
BHMW | Measurement Range | +0.0/+19.9 KILOHMS SINGLE INDICATOR 2ND RANGE |
BHMW | Measurement Range | +0.0/+199.9 MICROAMPERES, AC SINGLE INDICATOR 6TH RANGE |
BHMW | Measurement Range | +0.0/+199.9 MILLIAMPERES, AC SINGLE INDICATOR 10TH RANGE |
BHMW | Measurement Range | +0.0/+19.9 MEGOHMS SINGLE INDICATOR 5TH RANGE |
BHMW | Measurement Range | +0.0/+19.9 MILLIAMPERES, AC SINGLE INDICATOR 9TH RANGE |
BHMW | Measurement Range | +0.0/+199.0 KILOHMS SINGLE INDICATOR 3RD RANGE |
BHMW | Measurement Range | +0.0/+199.9 MILLIVOLTS, AC SINGLE INDICATOR 16TH RANGE |
BHMW | Measurement Range | +0.0/+1999.9 KILOHMS SINGLE INDICATOR 4TH RANGE |
BHMW | Measurement Range | +0.0/+1999.9 MILLIAMPERES, AC SINGLE INDICATOR 11TH RANGE |
BHMW | Measurement Range | -19.9/+19.9 MILLIAMPERES, DC SINGLE INDICATOR 13TH RANGE |
BHMW | Measurement Range | -199.9/+199.9 MICROAMPERES, DC SINGLE INDICATOR 7TH RANGE |
BHMW | Measurement Range | -1999.9/+1999.9 MILLIAMPERES, DC SINGLE INDICATOR 15TH RANGE |
BHMW | Measurement Range | -199.9/+199.9 MILLIAMPERES, DC SINGLE INDICATOR 14TH RANGE |
BHMW | Measurement Range | -1.9/+1.9 MILLIAMPERES, DC SINGLE INDICATOR 12TH RANGE |
CTWN | Operating Voltage Rating In Volts | 6.0 DC NOMINAL |
AWZJ | Power Source | INTERNAL |
ABKW | Overall Height | 2.500 INCHES NOMINAL |
ABHP | Overall Length | 5.700 INCHES NOMINAL |
ABMK | Overall Width | 4.900 INCHES NOMINAL |
FEAT | Special Features | MEASUREMENT RANGE CONTD: SINGLE INDICATOR,17 RANGE M199.9/P199.9 MILLIVOLTS; 18 RANGE P0.0/P199.9 OHMS; 19 RANGE P0.0/P1.9 ACV; 20 RANGE P0.0/P19.9 ACV; 21 RANGE P0.0/P199.9 ACV; 22 RANGE P0.0/P750.0 ACV; 23 RANGE M1.9/P1.9 DCV; 24 RANGE M19.9/P19.9 DCV; 25 RANGE M199.9/P199.9 DCV; 26 RANGE M1100.0/P1100.0 DCV |
STYL | Style Designator | RECTANGULAR OR SQUARE |