6625-01-071-2539

COUNTER,ELECTRONIC,DIGITAL READOUT


6625-01-071-2539 (6625010712539, 010712539)
Part Number (1 listing): 1018
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 3 Feb 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-071-2539 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
10183 - Design Control Reference9 - No Longer UsedTRAK MICROWAVE CORP-WESTERN DIV  29111      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-071-2539 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625010712539T297-A26835X43APU3 Feb 1979
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

010712539

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-071-2539

T297-A

Federal Item Identification Guide (FIIG_4065)

26835

Item Naming Code (INC_4080)

3 Feb 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-071-2539 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G51000C1 Apr 1991
ZH011 Oct 2009
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-071-2539 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
439451D1018  29111  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

51

Reference Number Action Activity Code (RNAAC_2900)


Environmental Protection Agency, Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-071-2539 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Feb 1979
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Feb 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-071-2539 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
51
Code Definitions

51

Originating Activity Code (ORIG_ACTY_CD_4210)


Environmental Protection Agency, Washington, DC 20406

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-071-2539 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFHSAccessory Component Quantity1 AND 1
AZCGAccessory Component Name6 FT. COAXIAL CABLE; MALE BNC 1 END
AKVZAccessory Identifying Number2702 PART NO.
AKVYAccessory Controlling AgencySYSTRON-DONNER CORP
BFJCAccuracy RatingPORM 1 COUNT PORM TIME BASE ACCURACY
ACDCCurrent TypeAC
BFQRDisplay Positioned Decimal PointPROVIDED
BFQPDisplay Digit Quantity7
BFQSDisplay Storage FacilityINCLUDED
BFQQDisplay Units IndicatorINCLUDED
BFJFGate Time0.001 SECONDS MINIMUM AND 10.000 SECONDS MAXIMUM
BFRFFrequency Output Amplitude6.0 VOLTS PEAK TO PEAK
BFJBFrequency Range+0.000/+50.000 MEGAHERTZ F1 INPUT RATIO AND +0.010/+2.000 MEGAHERTZ F2 INPUT RATIO AND +0.000/+100.000 MEGAHERTZ OVERALL
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
BFHZMeasurement TypeFREQUENCY AND RATIO AND TIME
APTSOutput Frequency Rating0.1 HERTZ MINIMUM AND 1000000.0 HERTZ MAXIMUM
BFRDOutput Frequency WaveformRECTANGULAR WAVE
BFQYInclosure Surface Treatment And LocationPAINT CASE
ALSFInternal Battery AccommodationNOT INCLUDED
BFQHRatio DisplayF1/F2 TIMES MULTIPLIER X 1000000
BFJGSensitivity Rating0.1 VRMS F1 INPUT; 1 VRMS F2 INPUT
ABKWOverall Height5.250 INCHES NOMINAL
ABHPOverall Length18.000 INCHES NOMINAL
ABMKOverall Width17.500 INCHES NOMINAL
AMSEVoltage Rating115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
ABJLWattage Rating In Watts125.0
BFRBStandard Frequency Output FeatureINCLUDED


Back to Top