6625-01-074-9385

OSCILLOSCOPE


6625-01-074-9385 (6625010749385, 010749385)
Part Number (1 listing): 1474
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 11 Apr 1979

Replacement NSN:

6625-00-583-6578

Replacement Date: 23 Jul 1986

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-074-9385 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
14743 - Design Control Reference2 - Production ItemB&K PRECISION CORPORATION  08098      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-074-9385 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625010749385T320-G00357X43APU11 Apr 1979
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

010749385

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-074-9385

T320-G

Federal Item Identification Guide (FIIG_4065)

00357

Item Naming Code (INC_4080)

11 Apr 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-074-9385 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G51000C1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-074-9385 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
432451D1474  08098  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

51

Reference Number Action Activity Code (RNAAC_2900)


Environmental Protection Agency, Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-074-9385 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX01TX023 Jul 1986 6625005836578 3 Apr 1983
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

23 Jul 1986

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6625-00-583-6578

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3 Apr 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-074-9385 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
51
Code Definitions

51

Originating Activity Code (ORIG_ACTY_CD_4210)


Environmental Protection Agency, Washington, DC 20406

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-074-9385 Submit RFQ
MRCDecoded RequirementClear Text Reply
BDJDAccuracy Range In Percent-1.0/+1.0
BHDDAmplifier Deflection Sensitivity ProvisionPROVIDED
BHDZAmplitude Calibrating Voltage WaveformSQUARE WAVE
BHFBCalibrating Peak To Peak Amplitude495.0 MILLIVOLTS MINIMUM AND 505.0 MILLIVOLTS MAXIMUM
ACDCCurrent TypeAC
BGSDExpanded SweepPROVIDED
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
BHDPFrequency Response RatingPROVIDED
BHDGHorizontal Deflection Sensitivity Voltage Rating5.0 MILLIVOLTS CW MEGAHERTZ AND 5000.0 MILLIVOLTS PEAK MEGAHERTZ
BHDHInput Intensity Modulation FeaturePROVIDED
BGQKScreen Size8 BY 10 CENTIMETERS
BGQQSingle Trigger Sweep Duration0.2 MICROSECONDS MINIMUM AND 500.0 MICROSECONDS MAXIMUM
ABKWOverall Height190.0 MILLIMETERS NOMINAL
ABHPOverall Length375.0 MILLIMETERS NOMINAL
ABMKOverall Width260.0 MILLIMETERS NOMINAL
FAAZPhaseSINGLE
BHDJVisual Modulation Sensitivity Voltage Rating5.0 VOLTS MINIMUM AND 50.0 VOLTS MAXIMUM
BHDFVertical Deflection Sensitivity Voltage Rating5.0 MILLIVOLTS MINIMUM PEAK TO PEAK PER CENTIMETER AND 5000.0 MILLIVOLTS MAXIMUM PEAK TO PEAK PER CENTIMETER
AMSEVoltage Rating117.0 VOLTS NOMINAL AND 234.0 VOLTS NOMINAL
BHDQX-Axis Frequency Response Rating10.0 HERTZ MINIMUM AND 2000000.0 HERTZ MAXIMUM
BHDRY-Axis Frequency Response Rating10.0 HERTZ MINIMUM AND 30000000.0 HERTZ MAXIMUM
BGQLSweep CircuitsINCLUDED


Back to Top
Back to Top